5.0 OPTIONAL BLOWER INSTALLATION | 15 |
|
!WARNING
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING
ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER CORD BENEATH THE APPLIANCE.
5.0.1Turn off the electrical power and the gas supply to the appli- ance insert.
5.0.2Open the glass door and remove the logs and fibre bricks, if installed.
5.0.3Remove the front blower access cover held on with 4 screws.
5.0.4 Remove the rear blower access cover. NOTE: Check the | FIGURE 8 |
blower gasket for damage. Replace if damaged. |
|
5.0.5 Disconnect the two blower wires. Remove the blower | FRONT BLOWER ACCESS COVER |
from the mounting plate and replace. For thermodisc |
|
replacement: Remove the mounting bracket secured |
|
to the underside of the burner base. Remove the |
|
thermodisc from the bracket and replace. |
|
5.0.6Reconnect the two wires.
access covers. Replace the logs. Close the fire view-
ing door.REAR BLOWER ACCESS COVER
5.0.7Turn the gas supply and electricity back on. Because the blower is thermally activated, when turned on, it will automatically start approximately
the output of heat.
Drywall dust will penetrate into the blower bear- ings causing irreparable damage and must be prevented from coming into contact with the blower or its compartment. Any damage result- ing from this condition is not covered by the warranty policy.
THERMODISC / BRACKET
ASSEMBLY