Napoleon Fireplaces GDI30 manual Optional Blower Installation

Models: GDI30

1 26
Download 26 pages 62.55 Kb
Page 15
Image 15
5.0 OPTIONAL BLOWER INSTALLATION

5.0 OPTIONAL BLOWER INSTALLATION

15

 

!WARNING

RISK OF FIRE AND ELECTRICAL SHOCK.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.

ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER CORD BENEATH THE APPLIANCE.

5.0.1Turn off the electrical power and the gas supply to the appli- ance insert.

5.0.2Open the glass door and remove the logs and fibre bricks, if installed.

5.0.3Remove the front blower access cover held on with 4 screws.

5.0.4 Remove the rear blower access cover. NOTE: Check the

FIGURE 8

blower gasket for damage. Replace if damaged.

 

5.0.5 Disconnect the two blower wires. Remove the blower

FRONT BLOWER ACCESS COVER

from the mounting plate and replace. For thermodisc

 

replacement: Remove the mounting bracket secured

 

to the underside of the burner base. Remove the

 

thermodisc from the bracket and replace.

 

5.0.6Reconnect the two wires. Re-install the blower gas- Manual backgroundManual background ket. Reattach the blower mounting plate and blower

access covers. Replace the logs. Close the fire view-

ing door.REAR BLOWER ACCESS COVER

5.0.7Turn the gas supply and electricity back on. Because the blower is thermally activated, when turned on, it will automatically start approximately 5-15 minutes after lighting the appliance insert and will run for ap- proximately 30-45 minutes after the appliance insert has been turned off. Use of the fan increases

the output of heat.

Drywall dust will penetrate into the blower bear- ings causing irreparable damage and must be prevented from coming into contact with the blower or its compartment. Any damage result- ing from this condition is not covered by the warranty policy.

THERMODISC / BRACKET

ASSEMBLY

W415-0806 / 06.28.09