AIR COOLED CHIMNEY INSTALLATION

18

AIR COOLED CHIMNEY INSTALLATION

1.Remove the knock out.

2.Cut away the insulation to gain access to the ring.

3.Remove the ring secured by four screws.

4.Slide the starter collar through the insulation wrap and affix using the four screws removed in step 3.

5.Secure the inner liner of the chimney to the fireplace 8" collar using 3 screws supplied with the starter collar (W170- 0098).

6.Follow the chimney manufacturer's instructions for in- stalling the chimney.

AIR COOLED CHIMNEY REQUIREMENTS

Use only the following brand and type of chimney.
Chimney Components
FMI 8DM

 

 

12" Chimney Section

12-8DM

 

 

18" Chimney Section

18-8DM

 

 

24" Chimney Section

24-8DM

 

 

36" Chimney Section

36-8DM

 

 

48" Chimney Section

48-8DM

 

 

Offsets

30E-8DM

 

 

Flashing

6F8 or 12F8

 

 

Chimney Cap

RTL-8HT

 

 

Roof Support

38 RS

 

 

Firestop

FS-8DM

 

 

Chimney Components

Wolf Steel

 

 

Starter Collar

NZAC-KT

 

 

FINISHING

ATTACHING THE HANDLE AND

AIR CONTOL KNOB

The door latch is adjusted by moving the washer from one side of the latch to the other. Tighten the outer nut to secure the latch.

Install the air control threaded rod and knob.