Napoleon Fireplaces NZ6000 manual Chimney Installation, The diameter of the chimney is

Models: NZ6000

1 32
Download 32 pages 19.26 Kb
Page 14
Image 14
CHIMNEY INSTALLATION

14

5Place brass washers onto

the faceplate hinge bushing (2 extra washers are sup- plied in order to level the doors if needed).

6

Install the air c o n t r o l threaded rod and knob.

Slide the door hinge pin into the faceplate hinge bushing.

To remove the doors, open them slightly and lift them out of the faceplate hinge bushings.

CHIMNEY INSTALLATION

Araised hearth together with the fireplace built on a raised platform is recommended for easier wood loading and fire viewing.

The diameter of the chimney is 8".

A chimney venting the fireplace shall not vent any other appliance.

The minimum overall chimney height from the top of the fireplace is 15 feet.

The maximum overall chimney height from the top of the fireplace is 34 feet.

Factory-built chimney systems for use in dwellings constructed for three or more families must be enclosed above the room in which the fireplace is located. This enclosure must have a fire resistance rating equal to or greater than that of the floor or roof assembly through which they pass.

If the chimney system is enclosed within the attic area, a rafter radiation shield is required.

The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA.

The chimney must extend at least 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof or building within 10 feet.

If the chimney extends more than 5 feet above the roof, it must be secured using a roof brace or guide wires.

Ensure that minimum clearances are maintained.

Portions of the chimney that extend through accessible spaces must always be encased to avoid personal contact with the chimney and thereby avoid damage to the chimney.

A raincap must be installed to avoid internal damage and corrosion.

The chimney must be supported at a maximum of 20 foot intervals (approx. 200 lbs/20 ft).

This fireplace was tested to CAN /ULC S610 Standard for Factory Built Fireplaces, and to UL 127 Factory Built Fireplaces. This Factory Built Fireplace is certified to burn Fire Wood. The Factory Built Fireplace model: NZ6000 has met test criteria for Zero Clearance Installation to Combustible Surfaces.

Any 8" diameter chimney listed to these standards may be installed. In accordance with these standards, the unit may also be connected to any chimney listed to CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103HT for the United States.

Installation of all types of factory-built chimney systems is to be in accordance with the chimney manufacturers in- stallation instructions. An appropriate chimney manufac- turers anchor base plate and anchor base plate gasket is required in order to initiate their system. Use the high tem- perature gasket, supplied, to seal between the anchor plate and the fireplace top. Air cooled chimney systems are not recommended in colder climates.