IMPORTANT DO’S AND DON’TS

DO'S

Read the entire instruction manual before operating the gas grill.

Maintain proper clearance to combustibles (10" to rear and sides). Additional clearance is recommended near vinyl siding or large panes of glass.

Leak test the unit before initial use, annually and whenever any gas components are replaced.

Follow lighting instructions carefully when operating grill. Burner controls must be off when turning supply cylinder valve on.

Ensure sear plates are positioned properly according to sear plate installation instructions.

Clean grease tray and sear plates often to avoid build-up which may lead to grease fires. Allow hot grease to cool before cleaning.

Remove warming rack before lighting rear burner. (The extreme heat will damage the warming rack.)

DON'TS

Do not attempt to use a cylinder which is not equipped with a QCC1 type connection.

Do not route hose underneath drip pan - proper hose clearance to bottom of unit must be maintained.

Do not use condiment tray to store lighters, matches or any other combustibles.

Do not locate unit under unprotected combustible construction.

Do not leave grill unattended when operating.

Do not light burners with lid closed.

Do not move grill when hot or operating.

Do not attempt to heat unopened cans or other food containers on the grill. A buildup of pressure may cause the container to explode.

Do not use a pressure washer to clean any part of the unit.

GENERAL INFORMATION

THIS GAS BARBECUE IS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CAN/CGA-1.6-M95 AND ANSI Z21.58 -1995 RESPECTIVELY FOR OUTDOOR GAS GRILLS and should be installed to conform with local codes. In absence of local codes, install to the current CAN1-B149.2 Propane Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States.

If a rotisserie motor is used, it must be electrically grounded in accordance with local codes or, in absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the National Electrical Code, ANSI/NFPA 70 in the United States.

USE ONLY THE PRESSURE REGULATOR AND HOSE ASSEMBLY PROVIDED WITH THIS BARBECUE. REPLACEMENT PRES- SURE REGULATORS AND HOSE ASSEMBLIES MUST BE SPECIFIED BY THE MANUFACTURER. DO NOT STORE PROPANE CYLINDER OR SPARE CYLINDER ON THE SHELF BENEATH THE BARBECUE.

The regulator supplies a pressure of 11 inches water column to the gas grill and has a QCC1 type fitting. Cylinders to be used with this unit must be supplied with a Sherwood #3349 QCC1 cylinder valve. A QCC1 cylinder has a positive seating connection, which will not allow gas flow until a positive seal has been achieved. It is also equipped with an excess flow device. In order to attain full flow to the barbecue, the valves must be in the off position when the cylinder valve is turned on.

PROPANE CYLINDER SPECIFICATIONS: A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in accordance with the specifications for LP-gas cylinders of the Canadian Transport Commission (CTC) or the US Department of Transporta- tion (DOT). This appliance has been designed for use with a 20lb. (9.1 kg) size propane cylinder only (not supplied).

The propane cylinder must be provided with a shut-off valve terminating in a propane cylinder valve type QCC1, and a safety relief device having direct communication with the vapour space of the cylinder. The cylinder supply system must be arranged for vapour withdrawal and the cylinder shall include a collar to protect the cylinder valve. The cylinder shall incorporate an OPD

4 (overfill protection device).