Regency Z2510L Installation, Outside Air Kit, Installing The Blower Systems

Models: Z2510L

1 24
Download 24 pages 55.93 Kb
Page 13
Image 13
INSTALLING THE

INSTALLATION

INSTALLING THE

WIRING THE WARMHEARTH

OUTSIDE AIR KIT

Combustion air is fed to the fi rebox through a connection on the rear lower left side of the unit. A free fl owing supply of air must be available to this opening at all times. Combustion air may be taken from inside the building if the local building code allows, but performance may suffer. Also, it must go through the 4 in. duct to the connection on the left hand side.

Field wire main power supply to fi replace for fan kit. (All electrical connections should only be performed by a licensed/certifi ed electrician).

CAUTION: Label all wires prior to discon- nection when servicing controls. Wiring errors can cause improper and dangerous operation.

Air drawn from the interior of the building will affect the performance of gas or oil furnaces, and exhaust fans and fan driven appliances. This may cause a negative pressure in the house allowing smoke to back into the home. The preferred source of combustion air is from outside the building. If possible, install the kit on the wind loading side of the building not the leeward or (negative pressure) side.

Note: Do not obtain combustion air from attic, garage or other enclosed space.

1)Putthesuppliedinsulatedairducttoanearby exterior wall. Maximum length of duct is 20 ft. (6.1m). Duct length should be kept to a minimum and as straight as possible. Note: 5 ft. only is supplied with unit. If more than 5 ft. is used, increase the diameter of the duct. Termination should be in an area with good air fl ow.

INSTALLING THE BLOWER SYSTEMS

The WarmHearth Fireplace has been designed to meet a wide range of heating requirements. The radiant heat (through the large glass area) combined with the naturally convected heat, allows the WarmHearth Fireplace to adequately heat an average WIRING THE WARMHEARTHOUTSIDE AIR KITINSTALLING THE BLOWER SYSTEMSOutside Air Inlet must be 6 ft. belowthe chimney termination pointOPTION 1Manual backgroundManual background

sized room. A blower is recommended to assist in heating a larger area or one with wall separations. Through the

use of two separate blower systems,

Regency has developed the three basic blower wir-

ing options listed in the diagrams below. Please read all the descriptions before deciding which option is best suited for your application.

2)Ensure that your air source is not close to automobile exhaust, gas meters or other vents.

3)Cut a 4-1/4 in. hole through the wall and mount the outside air kit.

4)Attach the two ends of the duct (making sure not to damage the insulating cover) after installing the fl ange on the fi replace side. Duct must be secured by screws or clamp.

Outside Air Inlet must be 6 ft. below

the chimney termination point

Blower switch box slides into bottom louver assembly and is screwed into place. Place label on outside of louver as shown.

OPTION 1

Internal Blower with Thermo-Disc

The thermodisc provides the user with more convenient control. By leaving the auto/man switch on AUTO, the thermodisc will shut the fan off automatically when the fi replace is too cool to provide adequate heat.

1)Slide blower under side clips (see directional arrows on diagram) and wire to terminal box. Note: hardwire terminal box before drywalling.

2)Blower switch box slides onto bottom louver and is screwed into place.

3)Place sticker on outside of bottom louver.

Regency Z2510 WarmHearth

13

Page 13
Image 13
Regency Z2510L installation manual Installation, Outside Air Kit, Installing The Blower Systems, Wiring The Warmhearth