Regency Z2510L Installation, Installing Your Central Heating System, Materials Required

Models: Z2510L

1 24
Download 24 pages 55.93 Kb
Page 15
Image 15
INSTALLATION

INSTALLATION

5)Install the connector collar into the unit making sure it is pushed all the way down. Reach through the upper louver opening and snip and bend out the lower edge of the collar in at least 4 places inside the fi replace with pliers so it can't be pulled out.

Flex Vent

Use high temperature silicone to seal the

2)

Metal ducting, grills and distribution boxes.

block-off plate to the unit. If necessary drill

 

(Installer Supplied)

extra holes in the plate and the unit and

3)

Ducting is tested at 1 in. clearance to fram-

secure with extra screws.

 

 

ing for the fi rst 6 feet and 1/2 in. thereafter

Note: Make sure the block-off plate is fl ush and

 

and no stand-offs are required. All ducting

fastened tightly to the WarmHearth.

 

should be insulated to reduce heat loss.

6)Slide the collar into the flex duct. secure with an adjustable clamp. Snip and bend out the outer edge of the collar in at least 4 places inside the frame so it can't be pulled out.

7)Drill holes or use nails to attach the Vent Frame to the wall. Note: holes in frame are used to attach the Vent cover.

IMPORTANT: Make sure the front edge of the collar is flush with the front edge of the air vent frame.

Note: The flex duct can easily be trimmed shorter or stretched longer.

Note: Termination boxes require a 14-1/2"W x 15-3/8"H opening in com- bustible materials.

8)Locate and install the lower air vent next. A 7-3/4" x 7-3/4" opening is required to fi t the frame that is supplied. The vent must be installed in the chase and should be within 12" of the fl oor.

WARNING: Lower air vent MUST be installed in all applications, otherwise serious overheating of the chase may result.

9)Fastentheblock-offplatetotheWarmHearth using the existing holes that normally secure the louvers, using the louver screws. Make sure the top edge is up.

Important:Atight joint between ma- sonry and the fireplace is necessary to prevent heat from rolling up the front to the Face Header.

INSTALLING YOUR CENTRAL HEATING SYSTEM

The WarmHearth may be used as a central forced air heating unit by adding ducting and a fan.

Materials Required:

1)Blower requirements: see Options 2 and 3 in section "F) Installing the Blower Sys- tems"

CAUTION: Blowers must meet specificationslisted(refertoInstall- ing the Blower Systems section). A home fire may result from the use of substitute parts.

Installation

1)Remove screws from one of the vent hole covers "A" (but not both) on top of the WarmHearth.

2)Take one way duct vent pipe and rotate in hole to cut through 4 in. of insulation. Remove insulation from pipe.

3)Remove screws on cover "B" and slide it to the back.

4)Install the one way valve making sure it is pushed all the way down. Shutters should

Central Heat Option

Regency Z2510 WarmHearth

15

Page 15
Image 15
Regency Z2510L Installation, Installing Your Central Heating System, Materials Required, Central Heat Option