DO NOT USE AFLAME TO LEAK TEST.

LEAKTESTING: Thismust be done before initial use, annually and whenever any gas components are replaced or serviced. Nosmoking
whileperforming this test, and remove all sources of ignition. See
LeakTesting Diagram
forareas to check.
1.Turn all burners controls to off. Turn supply valve on.
2.Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
3.Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.
4.If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer.Do
notuse the appliance until the leak has been corrected.
5.Turn off gas supply.
LEAK TESTING INSTRUCTIONSGAS HOSE
Ifthe hose and regulator are not included by the manufacturer, then only hoses and regulators which meet national and regional codes
areto be used.
Do not connect the appliance to a permanent gas installation.
Ensure that the hose does not come into contactwith grease, other hot drippings, or any hot surfaces on the appliance.
Checkhose regularily. Inthe case of rips, melting or wear, replace hose before using the appliance.
The recommended hose length is 0.5m. Thehose must not be longer than 1.5m.
Ensurethat the hose is twist and kink free when installed.
Replacethe hose before expiry date printed on the hose.
REGULATOR
Thefollowing table lists input values for the appliance.
BURNER ORIFICESIZE HEATINPUT GASUSAGE (TOTAL)
I II (TOTAL) PROPANE BUTANE
MAIN #60 1.45mm 13.2 kW 944 g/h 960 g/h
BACK #58 1.5mm 4.1 kW 293g/h 298 g/h
SIDE #69 #57 2.3 kW 164g/h 167 g/h
CertifiedGases / Pressures - Check rating plate to ensure that it corresponds with following list.
Theregulators for both butane and propane must have a rating of at least 1200 g/h. Do not tamper with or modify regulator. Useonly
regulatorswhich supply the pressure listed in the table above.
Gas Category I3B/P(30) I3+(28-30/37) I2H(20) I2E(20)
Orifice Sizes (s ee above) I I II II
Gases/ Pressures Butane30mbar
Propane30mbar
Butane28-30mbar
Propane37mbar
NaturalGas 20mbar NaturalGas 20mbar
Countries CZ, DK, FI, GR,
NL, NO, SE BE, CH,CZ, ES,
FR,GB,IE,IT,
PT
AT,CH,CZ,DK,
ES, FI,GB, GR,
IE,IT,NO,PT,SE
DE, LU