Chapter 3 Signal Connections
© National Instruments Corporation 3-9 DAQCard-1200 User Manual

Figure 3-3. Differential Input Connections for Grounded Signal Sources

With this type of connection, the instrumentation amplifier rejects both the

common-mode noise in the signal and the ground-potential difference

between the signal source and the DAQCard-1200 ground, which is shown

as Vcm in Figure 3-3.

Differential Connections for Floating Signal Sources

Figure3-4 shows how to connect a floating signal source to a

DAQCard-1200 that is configured for DIFF input. Configuration

instructions are included in the Analog Input Configuration section of

Chapter2, Insta llation and Configuration.

+
+