Chapter 4 Theory of Operation
DAQCard-1200 User Manual 4-10 © National Instruments Corporation
For multiple-channel data acquisition, observing the data acquisition rates
in Table4-2 ensures 12-bit accuracy.
The recommended data acquisition rates in Table4-2 assume that voltage
levels on all the channels included in the scan sequence are within range for
the given gain and are driven by low-impedance sources.
Note If you use external conversions for single-channel acquisitions, the maximum
sampling rate is 90 kS/s.
Table 4-1. Analog Input Settling Time Versus Gain
Gain Setting Settling Time Recommended
1, 2, 5, 10 10 µs max
20 12 µs typ, 15 µs max
50 25 µs typ, 30 µs max
100 60 µs typ, 80 µs max
Table 4-2. DAQCard-1200 Maximum Recommended Data Acquisition Rates
Acquisition Mode Gain Setting Sampling
Rate
Single channel 1, 2, 5, 10, 20, 50, 100 100.0 kS/s
Multiple channel 1, 2, 5, 10 100 kS/s
20 83.3 kS/s
50 40.0 kS/s
100 16.6 kS/s