Table 14.
Specifications Valu e Comments
Operating
Temperature
0 ºC to +45 ºC. Meets IEC-60068-2-1 and IEC-60068-2-2.
Storage
Temperature
–25 ºC to +85 ºC. Meets IEC-60068-2-1 and
IEC-60068-2-2.
Operating
Relative
Humidity
10% to 90%, noncondensing. Meets IEC-60068-2-56.
Storage
Relative
Humidity
5% to 95%, noncondensing. Meets IEC-60068-2-56.
Storage
Shock
50 g, half-sine, 11 ms pulse. Meets IEC-60068-2-27. Test
profile developed in accordance with MIL-PRF-28800F.
Storage
Vibration
5 Hz to 500 Hz, 2.46 grms. Meets IEC-60068-2-64. Test
profile exceeds requirements of MIL-PRF-28800F, Class B.
Altitude 2,000 m maximum (at 25 °C ambient temperature)
Pollution
Degree
2 —