Site Preparation

9

Operating and Service Clearance Requirements

Location

Component

Distance

Reason

Above

7158

Printer

305 mm (12 in.)

Clearance to raise printer cover

 

 

 

 

 

 

7162

Printer

197 mm (7.75 in.)

Clearance to raise printer cover

 

 

 

 

 

 

7166

Printer

280 mm (11 in.)

Clearance to raise printer cover

 

 

 

 

 

 

7194

Printer

228 mm (9 in.)

Clearance to raise printer cover

 

 

 

 

 

 

7196

Printer

254 mm (10 in)

Clearance to raise printer cover

 

 

 

 

 

CRT Displays

50 mm (2 in.)

Clearance for CRT tilt

 

 

 

 

 

5972-1000

25 mm (1 in.)

Clearance for display tilt

 

2 x 20 Display

 

 

 

 

 

 

 

All units

153 mm (6 in.)

Service clearance

 

 

 

 

Left Side

All units

153 mm (6 in.)

Service clearance

 

 

 

 

 

Right Side

5972

2 x 20 Display

25 mm (1 in.)

Clearance for display rotation

 

 

 

 

 

All units

202 mm (8 in.)

Service clearance

 

 

 

 

 

Front

7162

Printer

127 mm (5 in.)

Clearance to open printer door

 

 

 

 

 

Drawer unit

330 mm (13 in.)

Clearance to open drawer

 

 

 

 

 

Behind

7162

Printer

76 mm (4 in.)

Clearance to raise printer cover

 

 

 

 

 

All units

153 mm (6 in.)

Service clearance

 

 

 

 

 

Page 21
Image 21