NEC manual Color Control Systems Only for MD212MC/MD213MC, Tools, English-12

Models: MD213MC

1 32
Download 32 pages 37.23 Kb
Page 14
Image 14

EXPANSION

Sets the zoom method.

FULL: The image is expanded to 1200 x 1600 (in portrait mode) or 1600 x 1200 (in landscape mode) for MD212MC and 1536 x 2048 (in portrait mode) or 2048 x 1536 (in landscape mode) for MD213MC/MD213MG, regardless of the resolution.

ASPECT: The image is expanded without changing the aspect ratio.

OFF: The image is not expanded.

CUSTOM: Refer to the ADVANCED OSD Controls menu section of the userÕs manual for detailed instructions.

When digital QXGA (1536 x 2048 or 2048 x 1536) of the medical monochrome signal is connected, this function does not operate (MD213MC/MD213MG only).

Color Control Systems (Only for MD212MC/MD213MC)

Color Control Systems: Nine preset color settings.

For preset settings 1, 2, 3 and 5, the following levels can be adjusted:

TEMPERATURE: Adjust the white temperature by increasing or decreasing this setting. A lower color temperature will make the screen reddish and a higher color temperature will make the screen bluish.

WHITE (White Balance): If TEMPERATURE needs further adjustment, the individual R/ G/ B/ levels of the white point can be adjusted. To adjust the R/G/B levels, CUSTOM must be showing as the TEMPERATURE selection. HUE: Adjusts the hue of each color*1. The change in color will appear on screen and the menu color bars will show the amount of adjustment.

SATURATION: Adjusts the color depth of each color*1. Press the ÒRIGHTÓ button and the color vividness increases.

OFFSET: Adjusts the color brightness of each color*1. Press ÒRIGHTÓ button and the color Brightness increases.

*1: RED, YELLOW, GREEN, CYAN, BLUE and MAGENTA.

NATIVE, sRGB: Original color presented by the LCD panel that is unadjustable.

PROGRAMMABLE: The color tone that was set up with the special application software is reflected.

CLEAR BASE: Color temperature setting for Clear Base x-ray film simulation.

BLUE BASE: Color temperature setting for Blue Base x-ray film simulation.

NOTE: To reset a poor image setting, turn on the monitor by using the power switch on the top (in portrait mode) or left side (in landscape mode) of the monitor while holding ÒRESETÓ and ÒSELECTÓ buttons at the same time.

Tools

SHARPNESS

This function is digitally capable of keeping independently for crisp image at any time. It is continuously adjustable to get as distinct or as soft an image as you prefer and is set independently for different timings.

DVI SELECTION

This function selects the DVI input mode (DVI-I). When the DVI selection has been changed, the computer has to be restarted.

AUTO: When using the DVI-D to DVI-D cable, the DVI SELECTION is DIGITAL.

When using the D-SUB to DVI-A cable, the DVI SELECTION is ANALOG.

DIGITAL: DVI digital input is available.

ANALOG: DVI analog input is available.

NOTE: Depending on the PC and Video card used, or when another Video signal cable is attached, this function may not operate.

VIDEO DETECT

Selects the method of video detection when more than one video input is connected.

FIRST: When current video input signal is not present, then the monitor searches for a video signal from the other video input port. If the video signal is present in the other port, then the monitor switches the video source input port to the new found video source automatically. The monitor will not look for other video signals while the current video source is present.

LAST: When the monitor is displaying a signal from the current source and a new secondary source is supplied to the monitor, then the monitor will automatically switch to the new video source. When current video input signal is not present, then the monitor searches for a video signal from the other video input port. If the video signal is present in the other port, then the monitor switches the video source input port to the new found video source automatically.

NONE: The Monitor will not search the other video input port unless the monitor is turned on.

English-12

Page 14
Image 14
NEC manual Color Control Systems Only for MD212MC/MD213MC, Tools, English-12

MD213MC specifications

The NEC MD213MC is a robust medical-grade display designed to meet the rigorous demands of healthcare environments. With a resolution of 2 megapixels, this monitor offers exceptional clarity and detail, essential for effective diagnosis and patient care. It features an active matrix TFT LCD panel that ensures superb image quality and consistency across various lighting conditions.

One of the standout features of the MD213MC is its high brightness level, which significantly enhances visibility and allows for clear viewing of images even in brightly lit examination rooms. The monitor supports a wide color gamut, ensuring that colors are reproduced accurately and that the display can handle diverse imaging applications.

The display is equipped with advanced medical imaging technologies, including a DICOM Part 14 compliance for grayscale images. This feature is crucial as it ensures that medical images, such as X-rays and MRIs, are displayed with the necessary contrast and brightness, assisting healthcare professionals in making informed decisions based on precise image analysis.

Another significant characteristic of the MD213MC is its ergonomic design. It includes a lightweight and slim profile, which makes it easy to mount in various clinical settings. The monitor can be adjusted for height, tilt, and swivel, enhancing the comfort of users during long hours of operation.

The MD213MC also incorporates an automated calibration feature that ensures consistent image quality over time. This is particularly important in medical settings, where even minor discrepancies in image display can lead to varying diagnostics.

Connectivity is another strong aspect of the NEC MD213MC. The monitor offers multiple input options, including DisplayPort and DVI, making it compatible with a wide range of medical imaging equipment. Additionally, the monitor includes USB ports for easy connection to peripheral devices, enhancing its versatility.

In terms of compliance, the NEC MD213MC adheres to stringent medical safety and performance standards, ensuring that it functions reliably in critical environments. Its combination of high-resolution imaging, ergonomic design, and advanced display technologies makes it an ideal choice for hospitals and clinics looking to enhance their imaging capabilities for improved patient outcomes. Overall, the MD213MC represents a significant advancement in medical display technology, providing healthcare professionals with the tools necessary for effective diagnosis and treatment.