Chapter 3 Functions of NEC Storage PathManager
C:\>spscmd -getlun -v
*** LogicalUnit #0 ***
State=0x0
Config=0x0
LBMode=0x0
LogialDiskNumber='00000'
ProductId='iStorage 2000 '
SerialNumber='1234123412341234'
> 0: Priority=2, PortNumber=4, PathId=0, TargetId=0, Lun=0
BusNumber=0, SlotNumber=9
Wwpn=34129078:56341221
> 1: Priority=1, PortNumber=5, PathId=0, TargetId=1, Lun=0
BusNumber=1, SlotNumber=1
Wwpn=34129078:56341223
*** LogicalUnit #1 ***
State=0x0
Config=0x0
@ 1: Priority=1, PortNumber=4, PathId=0,
BusNumber=1, SlotNumber=1
Wwpn=34129078:56341223
C:\>
- State: (not used)
- Config: (not used)
- LBMode: settings for dynamic load balancing
- LogicalDiskNumber: number given to a logical disk
- ProductId: product ID of NEC Storage
- SerialNumber: serial number given to an NEC Storage unit
- PortNumber: number given to a port
- PathId: ID of a path
- TargetId: ID of a target for SCSI
- Lun: number given to a logical unit
- BusNumber: PCI bus number of an HBA
- SlotNumber: PCI device number of an HBA
- Wwpn: WWpn (World Wide port name)