Chapter 3 Functions of NEC Storage PathManager
3.
.7.2 E
Ev
v
vent logs
3
3.7
7.
.2
2
Ee
en
nt
t
l
lo
og
gs
s
Among the pieces of information stored in the SPS logs, important information such as information related
to failover and failback will be outputted to the event log (system) by the log service.
Refer to the following table for the outputted event log information.
Table 3-1 Event log list
Source(*1) EventID(*1) Detected event LV Output details
257
(513)
Failover started Info Failover started%. %1 Date&Time %2
258
(514)
Failover was done Warn I/O Path was changed%. %1
Date&Time %2
259
(515)
Failover failed Err Failover failed%. %1 Date&Time %2
260 Failback started Info Failback started%. %1 Date&Time %2
261 Failback was done Info Failback finished successfully%. %1
Date&Time %2
262 Failback failed Err Failback failed%. %1 Date&Time %2
263 Failback completed Info Failback was already completed. %1
Date&Time %2
264 Start Changing
priority
Info Start Changing Path Priority%. %1
Date&Time %2
265 Changing Priority
was done
Info Path Priority was changed
successfully%. %1 Date&Time %2
266 Failed to change
Priority
Err Failed to change Path Priority%. %1
Date&Time %2
267 Start changing
LBMode
Info Start changing LoadBalancing Mode %. %1
Date&Time %2
268 LBMode was
changed
Info LoadBalancing Mode was changed
successfully%. %1 Date&Time %2
269 Failed to change
LBMode
Info Failed to change LoadBalancing
Mode%. %1 Date&Time %2
270 Path error Info Path error was detected%. %1
Date&Time %2
271 Path error Info Path error was detected%. %1
Date&Time %2
272 AFB started Info AutoFailback started%. %1
Date&Time %2
273 AFB was done Info AutoFailback was done and some paths
were recovered%. %1 Date&Time %2
274
(530)
Path was removed Info Path was removed%. %1 Date&Time %2
275 Effectiveness was
changed
Info Effectiveness of Path was changed%. %1
Date&Time %2
276 Failed to change
Effectiveness
Warn Failed to change Effectiveness of
Path%. %1 Date&Time %2
277 Mode changed Info Mode was changed successfully %. %1
Date&Time %2
ispsvb
(spsdsm)
278 Some Paths are not
redundant
Warn Some paths are not redundant
(*1) In NEC Storage PathManager 3.0 for Windows, Source and EventID in parentheses is used if any. In
this case, the information on details and Date&Time is not outputted.
III-26