1.PART NAMES AND FUNCTIONS
Press to display the explanation of the current selected function and available functions.
CSIG LEVEL ButtonPress to display the SIGNAL LEVEL menu. You can set the level for an RGB or component signal.
DGAMMA ButtonPress to display the GAMMA CORRECTON menu. You can select two options.
EADDRESS ButtonPress to display the ADDRESS menu. Pressing with CTL allows you to specify the address for the remote control.
FPIXEL CLK ButtonPress to display the PIXEL CLOCK adjustment screen. You can adjust a picture width to the screen by adjusting the clock frequencies to eliminate the vertical banding in the image.
GPIXEL PHASEPress to display the PIXEL PHASE adjustment screen. You can adjust the clock phase to reduce video noise, dot interference or cross talk. (This is evident when part of your image appears to be shimmering.)
HINPUT ButtonSelects menus and switches input signals.
ICAPTION ButtonPress to display the CLOSED CAPTION menu.
JINFO ButtonPress to display the various parameters and settings of the currently displayed image. Pressing with the CTL button displays some of items available.
KINPUT LIST ButtonPress to display the memory list of the recorded input signals.
LZOOM/PAN ButtonPress to display the ZOOM adjustment screen. The zoom function enlarge or reduce the projected image. Pressing with CTL displays the PAN adjustment screen. The pan function enlarge or reduce the selected part of an image.
MKELVIN ButtonPress to enter the KELVIN mode. You can adjust the color temperature.
NPOSITION ButtonPress to enter the position mode. You can adjust the horizontal, vertical position and horizontal, vertical blanking and image size.
The R and B buttons are used for Uniformity only.
PCURSOR ButtonsUsed for increasing and decreasing control levels, cursor movement and convergence adjustments.
QDELETE ButtonUsed to delete characters or numbers you typed.
RNORMAL ButtonReturns the standard level for each signal. When pressed once, the confirmation message will be displayed. When “YES” is selected and ENTER is pressed, the data will be returned to the standard level. While holding down the CTL button, press the NORMAL button to display the LOAD menu to select the LOAD (last stored level).
SSTORE ButtonMemorizes the adjustments setting of each signal sepa- rately.
When pressed once, the confirmation message “STORE?” will be displayed. When selecting “YES” and ENTER, the data will be stored in memory.
TEND ButtonEnds the adjustment mode.
UENTER ButtonExecutes menu selection and switches to selected input.
VCTL ButtonUsed in conjunction with other buttons, similar to a shift key on a computer.
13