Symptom

Cause

Solution

 

 

 

Link LED is off for a port

There is a problem with this

Make sure the cable is attached

that has a connection.

connection.

securely at both ends.

 

 

Make sure the cable is not damaged.

 

 

Check that the device being connected

 

 

to is powered on and operating

 

 

correctly.

 

 

If the connection is to a workstation,

 

 

make sure the workstation’s network

 

 

interface is installed and configured

 

 

correctly.

 

 

 

File transfer is slow or

Half- or full-duplex setting on

Make sure the attached device is set to

performance degradation

the switch and the connected

auto negotiate.

is a problem.

device are not the same.

 

 

 

 

A segment or device is

One or more devices are not

Verify that the cabling is correct. Be

not recognized as part

properly connected, or

sure all connectors are securely

of the network.

cabling does not meet

positioned in the required ports.

 

Ethernet guidelines.

Equipment may have been accidentally

 

 

disconnected.

 

 

 

FDX/COL LED is

Collisions are occurring

Some collisions are normal when

blinking yellow

on the connected segment.

the connection is operating in

excessively.

 

half-duplex mode.

 

Duplex modes are mismatched.

Recheck the settings of the device

 

 

attached to the RJ-45 port. Make

 

 

sure the attached device is set to

 

 

auto negotiate.

 

 

 

ACT LED is flashing

A network loop (redundant path)

Break the loop by ensuring that there

continuously on all

has been created

is only one path from any networked

connected ports and the

(see Figures 2-3 and 2.4).

device to any other networked device.

network is disabled

 

 

 

 

 