NTI NODEMUX SERIES UNIVERSAL KVM SWITCH

Dipswitches

The dipswitches located next to the RS232 connection (Fig. 8) are used to configure the baud rate and address of the NODEMUX. The default baud rate is 9600. The default address is 1. Use the charts below to change the baud rate and address as needed.

OFF

1 2 3 4 5 6 7 8 ON

Figure 17- RS232 Dipswitches

BAUD RATE

The baud rate can be changed by powering down the unit, changing the DIP switch, and then powering back up. This table shows how to set the baud rate.

 

DIP SWITCH

BAUD

 

 

 

 

RATE

4

 

3

2

 

OFF

 

OFF

OFF

300

OFF

 

OFF

ON

600

OFF

 

ON

OFF

1200

OFF

 

ON

ON

2400

ON

 

OFF

OFF

4800

ON

 

OFF

ON

9600

ON

 

ON

OFF

9600

ON

 

ON

ON

9600

DIP SWITCH

The unit powers up with a default baud rate of 9600 and a fixed data protocol of 8 data bits, no parity, and 1 stop bit. To change the baud rate, unit address, and loop back (more on the unit address and loop back later), an 8-SPST DIP switch on the panel near the DB-9 connectors can be used. This table shows the DIP switch functions and their default positions.

SWITCH

FUNCTION

DEF-

 

 

AULT

1

loop back

ON

2

baud rate 0

ON

3

baud rate 1

ON

4

baud rate 2

ON

5

unit address 0

ON

6

unit address 1

OFF

7

unit address 2

OFF

8

unit address 3

OFF

UNIT ADDRESS

To allow multiple units to be controlled from a single host port, the remote interface is designed to allow "daisy chaining" of up to 15 units. By setting the appropriate DIP switches, each unit can be given a unique address (1-15). Then the unit will only respond to commands on the bus if its address is embedded in the command. The "loop back" DIP switch should be ON for the last unit in the chain, and OFF for all other units. If only one unit is being controlled, DIP switch 1 should be left ON. This table shows how to set the unit address.

 

DIP SWITCH

 

UNIT ADDRESS

8

7

6

5

 

OFF

OFF

OFF

OFF

0 (not valid)

OFF

OFF

OFF

ON

1

OFF

OFF

ON

OFF

2

OFF

OFF

ON

ON

3

OFF

ON

OFF

OFF

4

OFF

ON

OFF

ON

5

OFF

ON

ON

OFF

6

OFF

ON

ON

ON

7

ON

OFF

OFF

OFF

8

ON

OFF

OFF

ON

9

ON

OFF

ON

OFF

10

ON

OFF

ON

ON

11

ON

ON

OFF

OFF

12

ON

ON

OFF

ON

13

ON

ON

ON

OFF

14

ON

ON

ON

ON

15

RS232 Interface Test Program

RS232 communication is configured using the RMTEST program, located on the supplied floppy disk. This software allows a user to test the functions of an NTI NODEMUX or Multi-user/Multi-platform switch RS232 interface. The RMTEST program generates a main menu with the 3 selections described below:

MAIN OPTIONS

 

1.

Matrix Options

- send commands to the unit.

2.

Setup Options

- set COM port, baud rate, and unit address

3.

Quit

- quit the program

13

Page 16
Image 16
Network Technologies ST-2U operation manual RS232 Interface Test Program, Dipswitches, 3 4 5 6 7 8 on