Network Technologies ST-NXM-U-HD manual RS232 INTERFACE TEST PROGRAM DESCRIPTION, Main Options

Models: ST-NXM-U-HD

1 27
Download 27 pages 39.46 Kb
Page 22
Image 22
RS232 INTERFACE TEST PROGRAM DESCRIPTION

CS - change single USER channel

FORMAT: CS AA,XX,YY<CR>

CS = "change single USER" command followed by at least one space

 

AA = unit address

 

XX = CPU to connect

 

YY = USER to change

RESPONSE:

*<CR> (command received and executed OK)

 

?<CR> (syntax or transmission error occurred)

RO - read single USER channel

FORMAT:

RO AA,XX<CR>

 

RO = "read USER" command followed by at least one space

 

AA = unit address

 

XX = USER to read

RESPONSE:

1) *<CR> (command received and executed OK)

 

?<CR> (syntax or transmission error occurred)

 

2) XX<CR> (XX = CPU connected)

RU - read unit size

FORMAT:

RU AA<CR>

 

RU = "read unit size" command followed by at least one space

 

AA = unit address

RESPONSE:

1) *<CR> (command received and executed OK)

 

?<CR> (syntax or transmission error occurred)

XX,YY<CR> (XX = # of CPU’s, YY = # of USERS)

RS232 INTERFACE TEST PROGRAM DESCRIPTION

This software allows a user to test the functions of an NTI server switch, matrix switch or Multi-user/Multi-platform switch RS232 interface. The program SERTEST along with the Matrix Switcher's Control Program (see page 18) is installed from the 3-1/4" floppy disc packaged with this switch. SERTEST generates a main menu with the 3 selections described below:

Main Options

Matrix Options

- send commands to the matrix unit.

Setup Options

- set COM port, baud rate, and unit address

About SERTEST

- display the program version

If Matrix Options is selected, the following menu is displayed:

MATRIX OPERATIONS

1)Reset Unit (1)

-send a reset command to the switch

-the current unit address is displayed in parentheses

2)Reset All Units

-send an internal reset command to all switches

3)Connect KVM Output/User to an Input/CPU

-connect an output to an input (KVM ports only)

4)Connect All KVM Outputs/Users to an Input/CPU

-connect all outputs to an input (KVM ports only)

5)Connect Audio Output/User to an Input/CPU

-connect an output to an input (Audio ports only)

6)Connect All Audio Outputs/Users to an Input/CPU

-connect all outputs to an input (Audio ports only)

7)Change Mute Status for Audio Output/User

-mute or un-mute the Audio port output

8)Change Volume for Audio Output/User

-change Audio port output volume

18

Page 22
Image 22