FINISHING YOUR FIREPLACE

FINISHING YOUR FIREPLACE

There is a wide variety of finishing material available for your fireplace from formal wall treatments with marble and mantels, to rustic wood paneling, stone or brick. Non- combustible materials used in this installation such as slate, tile, marble, etc. must be at least 1/2" thick.

IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREPLACE NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATERIAL.

Non-combustible facing materials such as marble, brick, or ceramic tile may overlap the black face of the fireplace up to the opening on either side of the fireplace. Seal all joints between the black fireplace face and the wall covering with a heat-resistant material such as rock, wool, insulation or mortar. Be sure to use high temperature adhesive or mortar when anchoring brick, stone, or tile to the face of the fireplace. Check to see whether man-made

brick and stone are made of non combustible materials before using them on the face of the fireplace. Some of these products contain combustible materials. Combustible wall coverings such as paneling or wallboard may not overlap the black face of the fireplace. The space between the wall covering and the fireplace should be sealed with a heat resistant material such as rock, wool, insulation or mortar.

NOTE: An “L” shaped steel lintel must be installed across the top of the firebox opening where facing materials such as brick or stone is used on the face of the firebox. It acts as a support/firestop. It should be attached to the face of the fireplace with screws and sealed to the fireplace with a heat-resistant sealer.

CLEARANCES

To ensure a safe installation, the following must be carefully observed.

1.Sidewall Clearances: Clearances from the side of the fireplace opening to any adjacent combustible wall should not be less than 7"right side, 7” left side. See Figure 4.

2.Ceiling Clearances: The ceiling height should not be less than 42" from the top of the fireplace opening.

3.Mantel Clearances: We have provided 3 different situations to position your mantel. See Figure 5.

4.Floor Clearances: No clearance is required if the appliance is installed per these instructions.

5.Front Clearances: 24” to combustible Materials.

SIDE WALL

FIGURE 4

 

 

 

 

2"NON-COMBUSTIBLE

 

 

 

 

 

 

 

 

 

 

MATERIAL

 

 

7" MIN.

 

 

 

 

 

 

 

42"MIN.

 

 

 

 

 

 

 

 

 

CLEARANCE TO

 

 

 

 

 

 

 

CLEARANCE

SIDE WALL

 

 

 

 

 

 

 

TO CEILING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEFT SIDE

 

 

 

 

 

 

 

RIGHT SIDE

 

 

 

 

 

 

 

 

 

 

 

 

FRONT

24” MIN. TO COMBUSTIBLE MATERIALS