INSTALLATION
FRONT DOOR
INSTALLATION
(packaged separately)
1)Open the two side panels.
2)Slide the door
ontothetwohinge |
|
pins making sure |
|
the two pieces |
|
are fl ush togeth- | er. |
See diagram 1. |
|
3)Close the door. The latch plate
must be cen- tered around the align- ment pin. See diagram
2.If the latch plate interferes with the cor-
ner of the stove you
may want to angle the | Diagram 1 |
| |
plate slightly so the door |
|
closes easier. |
|
4)The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by loosening the latch catch. See diagram 3.
Diagram 2
OPTIONAL
WALL THERMOSTAT
A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length:
Note: Preferable if the thermostat is installed on an interior wall.
Regency® offers an optional programmable thermostat but any
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 240V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
Thermostat
| Wire Size |
|
| Max. Length | ||||||||
| 14 GA. | 15.24 | m | |||||||||
| 16 GA. | 9.75 | m | |||||||||
| 18 GA. | 6.10 | m | |||||||||
| 20 GA. | 3.66 | m | |||||||||
| 22 GA. | 2.71 | m | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
Do not connect the millivolt re-
mote control wires to
the 240V wires.
3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.
FINAL CHECK
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:
1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes.
2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3)Check for proper draft.
CAUTION
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.
5)Remove the blue plastic protective coating from the glass.
6)Test the seal around the door by placing a piece of paper between the unit and the door, close the door and try to pull the paper out. If it slips out easily, then the door is not properly sealed.Tighten or loosen the latch. See diagram 3.
Diagram 3
Note: The door latch may require adjust- ment as the door gasket material compresses after a few fires and after glass replacement. Turn the latch catch inward or outward to loosen or tighten.
OPTIONAL REMOTE
CONTROL
Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi replace to that location, use Thermostat Wire Table.
2)Connect the wires as per the wiring diagram above.
20 | Regency® F39 Room Sealed Freestanding Gas Stove |