To remove F39 fan:

MAINTENANCE

7)Tighten side panels nuts using the following procedure:

a.tighten top & bottom outside corner nuts

(2)

b.tighten inside nuts (3)

c.tighten top & bottom inside corners (2)

8)Tighten the 10 nuts on center glass re- tainer.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

To remove F39 fan:

1) Unplug or disconnect power source to stove.

2) Remove all logs and the rear log support, then remove the 10 screws holding the ac- cess panel in place.

3) Unclip the black and white wires from the

fan motor.

4)Open both side doors and gently pull the

fl ex pipe away from the center, otherwise the fan can catch on the fl ex pipe during installation and tear the pipe. Do not tear or damage the fl ex pipe.

FAN MAINTENANCE

Ifyourfanrequiresmaintenanceorreplacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.

If the fan is damaged or needs repair, it shall be repaired by the manufacturer or its service agent or similiarily qualified person to avoid a hazard.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

Alternate Fan Access:

If the rear access cover is ac- cessible, it can be removed to provide access to the fan.

Replacing F39 Fan:

Reverse the above steps (1 - 5). If necessary install a new gasket before replacing the fan access panel. Make sure the fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding Instruc-

tions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

5)Lift fan off of the 2 pins, tip back and pull through fi rebox opening. Disconnect the green ground wire from the right side of the fan as soon as you can reach it.

26

Regency® F39 Room Sealed Freestanding Gas Stove

Page 26
Image 26
Regency F39-NG, F39-LPG Fan Maintenance, Electrical Grounding Instruc tions, To remove F39 fan, Alternate Fan Access