OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

Beforeoperatingthisappliance,proceedthrough the following check list.

1)

Read and understand these Instructions

 

before operating this appliance.

2)

Check to see that all wiring is correct and

 

enclosed to prevent possible shock.

3)

Check to ensure there are no gas leaks.

4)

Make sure the three pieces of door glass

 

are properly positioned. Never operate the

 

appliance with any of the glass removed or

 

with the door open.

5)

Verify that all fl uing and the cap is unob-

 

structed.

6)

Verify log placement. If the pilot cannot be

 

seen when lighting the unit - the logs or the

4)Turn the PILOT knob counterclockwise to pilot and align it with the arrow as shown in diagram above.

5)Push in PILOT knob all the way in and hold. Immediately push IGNITOR button until pilot lights. Continue to hold the PILOT knob in for approximately one minute, then release the PILOT knob. The pilot fl ame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing PILOT knob.

6)Turn PILOT knob counter clockwise to on.

7)Use the Burner ON/OFF switch to turn on the burner.

8)Rotate the HEAT control to adjust the fl ame height higher or lower.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

AUTOMATIC

CONVECTION

FAN OPERATION

Set the fan speed on control panel at the top rear of the unit to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and the unit cooled to below a useful heat output range the fan will shut off automatically.

embers have been incorrectly positioned.

7) The unit should never to turned off and on

without a minimum of a 60 second wait.

LIGHTING

INSTRUCTIONS

IMPORTANT: The PILOT knob cannot be turned from pilot to off unless it is partially depressed.

Note: Open the pedestal door of the unit before lighting the pilot. Once the

SHUTDOWN

INSTRUCTIONS

1)Use the Burner ON/OFF switch, thermostat or remote control to turn off the burner.

2)Push in the PILOT knob slightly and turn clockwise to off. Do not force.

3)Turn off all electric power to the appliance if service is to be performed.

FIRST FIRE

ADJUSTING FLAME

HEIGHT

pilot is lit, close the door. You should never operate the unit with the door open.

1)If the PILOT knob is in the off position proceed to Step 4.

2)Push in PILOT knob slightly and turn clock- wisetooff. Knobcannotbeturnedfrom pilot to off unless knob is pushed in slightly. Do not force.

3)Wait fi ve minutes to allow gas, that may have accumulated in the main burner compartment, to escape. If you smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step.

The FIRST FIRE in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on. When fi rst oper- ated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

Note: When the glass is cold and the appli- ance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

Your heater has an adjustable fl ame to tailor the look and heat output to your specific needs. It is adjusted by turning the fl ame adjustment dial on the gas control valve.

Turn clockwise to adjust the fl ame higher, counterclockwise for a lower fl ame.