Regency F39-NG, F39-LPG Maintenance Instructions, General Flue Maintenance, Gold-Plateddoors

Models: F39-LPG F39-NG

1 31
Download 31 pages 24.14 Kb
Page 24
Image 24
MAINTENANCE

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1) Always turn off the valve before cleaning.

For relighting, refer to lighting instructions.

Keep the burner and control compartment

clean by brushing and vacuuming at least

once a year. When cleaning the logs, use a

soft clean paint brush as the logs are fragile

and easily damaged.

2) Clean glass (never when unit is hot), appli-

ance, louvres, and door with a damp cloth.

Never use an abrasive cleaner. The gold

louvres (and optional gold door) may be

scratched if abrasives are used to clean

them.

The heater is fi nished in a heat resistant

paint and should only be refi nished with

heat resistant paint (not with wall paint).

Regency® uses StoveBright Paint - Metallic

Black #6309.

3) Make a periodic check of burner for proper

position and condition. Visually check the

flame of the burner periodically, making sure

the flames are steady; not lifting or floating. If

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALLAN AUTHORIZEDSERVICETECHNI- CIAN TO INSPECT THE APPLI- ANCE AND TO REPLACE ANY PART OF CONTROL SYSTEM ANDANYGASCONTROLWHICH HAS BEEN UNDER WATER.

CAUTION:ANYSAFETYSCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLEMATERIALSHOULDNOT BE PLACED ON OR NEAR THE APPLIANCE.

Incorrect fl ame pattern will have small, probably yellow fl ames, not coming into proper contact with the rear of the burner or thermopile.

Top View of pilot fl ame

GENERAL FLUE

MAINTENANCE

Conduct an inspection of the fl uing system semi-annually. Recommended areas to inspect as follows:

there is a problem, call an authorized service

person.

4) Caution:Labelallwirespriortodisconnection

when servicing controls. Wiring errors can

cause improper and dangerous operation.

5) The appliance and fl uing system must be

inspected before use, and at least annu-

ally, by an authorized fi eld service person,

to ensure that the fl ow of combustion and

ventilation air is not obstructed.

During the annual service call, the burners

should be removed from the burner tray

and cleaned. Replace the embers but do

not block the pilot.

6) Keep the area near the appliance clear and

free from combustible materials, gasoline,

and other fl ammable vapours and liquids.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED

7)Each time the appliance is lit, it may cause condensation and fog the glass. This condensation and fog is normal and will disappear in a few minutes as the glass heats up.

Never operate the appliance without the glass properly secured in place or with the door open.

8)Periodically check the pilot fl ames. Correct flame pattern has three strong blue flames: 1 fl owing around the thermopile and 1 around the thermocouple, and 1 fl owing across the rear of the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pat- tern, contact your Regency® dealer for further instructions.

1)Check the Fluing System for corrosion in ar- eas that are exposed to the elements.These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.

2)RemovetheCap,andshineaflashlightdown the Flue. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensa- tion, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLYSUPERVISEDWHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

GOLD-PLATED DOORS

 

The 24 carat gold plated fi nish on the door

 

requires little maintenance, and need only be

 

cleaned with a damp cloth. DO NOT use abra-

 

sive materials or chemical cleaners, as they may

 

harm the fi nish and void the warranty. Clean any

Top View of pilot fl ame

fi ngerprints off before turning the unit on. If the

 

door starts to discolour, check the gasket

 

seal and replace if necessary.

24

Regency® F39 Room Sealed Freestanding Gas Stove

Page 24
Image 24
Regency F39-NG, F39-LPG installation manual Maintenance Instructions, General Flue Maintenance, Gold-Plateddoors