INSTALLATION
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1)Make sure the valve is in the "OFF" posi- tion.
2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.
3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.
4)Light the pilot and turn the valve to "ON" position. Read manometer.
5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.
6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten
Valve Description
1)Gas on/off knob
2)Manual high/low adjustment
3)Pilot Adjustment
4)Thermocouple Connection
5)Main Operator
6)Outlet Pressure Tap (Manifold Pressure)
7)Inlet Pressure Tap (Supply Pressure)
8)Pilot Outlet
9)Main Gas Outlet
10)Flange Securing Screw Holes
11)Alternative TC Connection Point
12)Thermoelectric Unit
13)Additional Valve Mounting Hole
System Data
F39 with 40mj
Burner Inlet Orifi ce Sizes:
NG LPG
Burner #32 #50 2.95mm 1.78mm
Max. Input | NG | 40 Mj/h |
| LPG | 38 Mj/h |
Min. Input | NG | 20 Mj/h |
| LPG | 19 Mj/h |
|
| |
Supply Pressure |
| |
NG |
| min. 1.13 kPa |
LPG |
| min. 2.75 kPa |
Manifold Pressure
NG .94 kPa
LPG 2.55kPa
Electrical: 240 V. 1.13A 60Hz.
Circulation: 2 speed fan, 125/75 CFM.
Log Set: Ceramic fi ber, 7 per set.
| System Data | |
F39 Converted to 31mj | ||
|
| |
Burner Inlet Orifi ce Sizes: |
| |
NG | #37 | 2.65mm |
LPG | #52 | 1.6mm |
Max. Input - NG/LPG
31 Mj/h
Min. Input - NG/LPG
16 Mj/h
Supply Pressure |
|
NG | min. 1.13 kPa |
LPG | min. 2.75 kPa |
|
|
Manifold Pressure |
|
NG | .89 kPa |
LPG | 2.55kPa |
Electrical: 240 V. 1.13A 60Hz.
Circulation: Variable speed fan, 125/75 CFM.
Log Set: Ceramic fi ber, 7 per set.
AERATION
ADJUSTMENT
The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.
| F39 with 40mj |
|
NG: | Full open | |
LPG: | Full open | |
| F39 with 31mj |
|
NG | 6mm open | |
LPG | 10mm open |
Note: Anydamageduetocarboningresulting from improperly setting the aeration controls is NOT covered under war- ranty.