Regency F39-NG Aeration Adjustment, Valve Description, System Data F39 with 40mj, Installation

Models: F39-LPG F39-NG

1 31
Download 31 pages 24.14 Kb
Page 16
Image 16
Valve Description

INSTALLATION

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" posi- tion.

2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position. Read manometer.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.

6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten

Valve Description

1)Gas on/off knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection

5)Main Operator

6)Outlet Pressure Tap (Manifold Pressure)

7)Inlet Pressure Tap (Supply Pressure)

8)Pilot Outlet

9)Main Gas Outlet

10)Flange Securing Screw Holes

11)Alternative TC Connection Point

12)Thermoelectric Unit

13)Additional Valve Mounting Hole

System Data

F39 with 40mj

Burner Inlet Orifi ce Sizes:

NG LPG

Burner #32 #50 2.95mm 1.78mm

Max. Input

NG

40 Mj/h

 

LPG

38 Mj/h

Min. Input

NG

20 Mj/h

 

LPG

19 Mj/h

 

 

Supply Pressure

 

NG

 

min. 1.13 kPa

LPG

 

min. 2.75 kPa

Manifold Pressure

NG .94 kPa

LPG 2.55kPa

Electrical: 240 V. 1.13A 60Hz.

Circulation: 2 speed fan, 125/75 CFM.

Log Set: Ceramic fi ber, 7 per set.

 

System Data

F39 Converted to 31mj

 

 

Burner Inlet Orifi ce Sizes:

 

NG

#37

2.65mm

LPG

#52

1.6mm

Max. Input - NG/LPG

31 Mj/h

Min. Input - NG/LPG

16 Mj/h

Supply Pressure

 

NG

min. 1.13 kPa

LPG

min. 2.75 kPa

 

 

Manifold Pressure

 

NG

.89 kPa

LPG

2.55kPa

Electrical: 240 V. 1.13A 60Hz.

Circulation: Variable speed fan, 125/75 CFM.

Log Set: Ceramic fi ber, 7 per set.

AERATION

ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

 

F39 with 40mj

 

F39-NG

NG:

Full open

F39-LPG

LPG:

Full open

 

F39 with 31mj

 

F39-NG

NG

6mm open

F39-LPG

LPG

10mm open

Note: Anydamageduetocarboningresulting from improperly setting the aeration controls is NOT covered under war- ranty.

16

Regency® F39 Room Sealed Freestanding Gas Stove

Page 16
Image 16
Regency F39-NG Aeration Adjustment, Valve Description, System Data F39 with 40mj, F39 Converted to 31mj, Installation