FLUING ARRANGEMENTS

INSTALLATION

FLUING ARRANGEMENTS

Horizontal Terminations for All Fluing Systems

The shaded areas in the diagram below show all allowable combina- tions of vertical runs with horizontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow).

LPG and NG:

Residential, Manufactured and Mobile

Homes Installations

The fl uing arrangements diagrammed below, have a min. of 75% (fl ue loss) efficiency with Fan Off, as required for manufactured homes. (Actual effi ciency may be as high as 85%)

Vertical Terminations Using Dura-Flue Fluing System for

Residential Manufactured and Mobile Homes

The shaded area in the diagram below shows all allowable combi- nations of straight vertical and offset to vertical runs with vertical terminations. Maximum two 45o elbows.

If the fl ue is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.

May be installed in Manufactured (Mobile) Homes after fi rst sale.

May be installed in Manufactured (Mobile) Homes after fi rst sale.

Flue Restrictor Position

To set the Flue restriction as indicated in the diagram, simply loosen the screws and push the fl ue restrictor plate to the correct position. Tighten the screws.

Flue Restrictor setting at

Flue Restrictor setting at

40 Mj/h

31 Mj/h