Regency F39-LPG, F39-NG installation manual Installation, Note The pipe seam should be facing down

Models: F39-LPG F39-NG

1 31
Download 31 pages 24.14 Kb
Page 11
Image 11
Note: The pipe seam should be facing down.

INSTALLATION

when cut will seat onto both the starter collar and the 90o elbow. Crimped section of rigid pipe seats into the 90o elbow. Only cut the uncrimped side of pipe.

Dismantle all pipe sections including fl ue terminal.

3)Attach the 4" dia. flex liner to the flue terminal ensuring that the fl ex overlaps the collar of the fl ue terminal by a minimum of

1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stain- less steel).

4)Attach the 2 ft. pipe section to the fl ue termi- nal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel).

Hint: Apply the sealant (Mill- Pac and/or high temperature silicone) to the outer pipe be- fore connecting the inner pipe.

#8 x ½" (13mm) Self Tapping, Stainless Steel

#8 x ½" (13mm) Self Tapping, Black

#8 x 1½" (38mm) Drill Point, Stainless Steel

Note: The pipe seam should be facing down.

Note: To make the installa- tion more aestheti- cally pleasing, we recommendframing out a square that the cap can be mounted on.

Note: If installing termination on a siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding. For vinyl siding standoff installation refer to the Dura-Flue Termination instruc- tions.

5)Slide the partially connected pipe and fl ue terminal assembly through the wall (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill point, stainless steel).

Note: The four screws provided for the flue cap should be replaced with ap- propriate fasteners for stucco, brick, concrete, or other types of sidings.

6)A bead of non-hardening mastic should be run around both the termination and vinyl sidingstandofftopreventwaterfromentering and to make a tight seal between the cap and the standoff.

7)Stretch the 4" dia. fl ex liner out fully and get a trial fi t of the liner onto the 4" dia. starter collar.

8)Cut the 4" dia. fl ex liner to the desired size.

Hint: leave an extra 12" to 16" of length, this will make the fi nal assembly easier to work with.

9)Secure the 4" dia. fl ex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel).

10)Slide the Decorative Wall Cover over the pipe sections.

11)Slide the 90o elbow (crimp end up) and the 2 ft. pipe section (crimp end up) over the 4" dia. fl ex liner.

12)Slide the trim collar over the pipe section to cover the joint.

13)Install the spring spacers onto the pipe sec- tions.

14)Secure the 4" dia. fl ex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel).

15)Attach the pipe section onto the starter collar by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" (black) screws. Pipe seams should be facing the wall.

16)Attach the 90oelbow onto the pipe section by sealing with Mill-Pac and/or high tempera- ture silicone and securing with 3 of the #8 x 1/2" screws (black).

17)Slide the 2 ft. pipe section onto the 90o el- bow. The fl ex may have to be compressed back in order for the pipe to properly mate to the elbow. Seal with Mill-Pac and/or high temperature silicone and secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down.

18)Install the trim collar over the starter collar and secure with a #8 x 1/2" screw (black).

If the pipe needs to be touched up, use only Stove Brite High Temperature Metallic Black Stove Paint.

NOTE: All inner joints must be sealed with Mill-Pac.

All outer joints may be sealed with high temperature silicone.

Regency® F39 Room Sealed Freestanding Gas Stove

11

Page 11
Image 11
Regency F39-LPG, F39-NG installation manual Installation, Note The pipe seam should be facing down