1)Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the fl uing system is attached. If this is the case, you may want to adjust the location of the unit.
2)Room Sealed pipe and fi ttings are designed with special
pipe and elbows to the ap- pliance adaptor with
pipe seams oriented towards the wall or ceiling, as much out of
view as possible. The
final positioning of the pipe and 90o elbow as- sembly is determined by the mounting
orientationofthe adaptor on the stove and twist- lockedforasolid connection.
Note:
a)
(diagram 1). Push the pipe sections completely together, then
Hint: Apply silicone to female end.
b)Horizontalrunsoffluemustbesupported everythreefeet.Wallstrapsareavailable for this purpose.
3)With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a 10" x 10" (inside dimensions) square hole. The center of the square hole should line up with the centerline of the
Diagram 1
horizontal pipe, as shown in diagram 2. Cut and frame the 10 inch square hole in the exterior wall where the fl ue will be terminated. If the wall being penetrated is constructed of
Note:
a)The horizontal run of fl ue should have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the fl ue to run downward. This could cause high temperatures and may present the possibility of a fi re.
F39:
Diagram 2
b)The location of the horizontal fl ue termi- nation on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Flue Terminal Locations dia- gram, refer to "Exterior FlueTermination Location" section.
4)If installing the fl ue termination to a wall with vinyl siding, the Vinyl Siding Standoff must be used. Attach the Vinyl Siding Standoff to the Horizontal FlueTermination, but first run a bead of
| Diagram 5 |
Note: | If installing termination on a siding |
covered wall, a vinyl siding standoff or fur- ring strips must be used to ensure that the termination is not recessed into the siding. The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
5)Before connecting the horizontal run of fl ue pipe to the fl ue termination, slide the black decorative wall thimble cover over the fl ue pipe, then slide the Wall Thimble (Part # 942) over the fl ue pipe.
6)Slide the appliance and fl ue assembly towards the wall carefully inserting the fl ue pipe into the fl ue cap assembly. It is impor- tant that the fl ue pipe extends into the fl ue cap a suffi cient distance so as to result in a minimum pipe overlap of
7)Install the Wall Thimble in the center of the 10" square and attach with wood screws.