Regency F39-NG, F39-LPG Installation Checklist, Clearances To Combustibles, This includes

Models: F39-LPG F39-NG

1 31
Download 31 pages 24.14 Kb
Page 6
Image 6
INSTALLATION

INSTALLATION

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this ap- pliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorised service person.An authorised service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

INSTALLATION

CHECKLIST

1)Check Clearances to Combustibles. Refer to the "Clearance to Combustibles" section.

2)Install Louvers. Refer to "Louver Installation" section.

3)Install fl ueing. Refer to the "Flueing" sec- tion.

4)Make gas connections. Refer to the "Gas Connection" section. Test the pilot. Must be as per diagram in the "Pilot Adjustment" section.

5)If necessary, convert NG to LPG. Refer to the "Conversion from NG to LPG" section.

6)Test Gas Pressure. Refer to the "Gas Pipe Pressure Testing" section.

7)Install log set. Refer to the "Log Set Instal- lation" section

8)Install Front Door. Refer to the "Front Door Installation" section.

9)Install Optional Features. Refer to the following sections where applicable:

a.Optional Wall Thermostat

b.Optional Remote Control

10)Final check. Refer to the "Final Check" section.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi r- ing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

CLEARANCES TO

COMBUSTIBLES

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide.

For example, if the appliance is set as indicated in one of the fi gures but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pictured.

Do not combine clearances from one type of installation with another in order to achieve closer clearances.

This unit can be installed on a solid combustible surface like a wood fl oor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

Use the minimum clearances shown in the diagrams below:

F39-NG & F39-LPG Clearances

A Side Wall to Unit

190 mm

B Back Wall to Unit

150 mm

E Side Wall to Unit

50 mm

F39-NG & F39-LPG Reference Dimensions

CBack Wall to Flue Centerline 11" / 280 mm D Side Wall to Flue Centerline 521 mm

F Side Wall to Flue Centerline 280 mm

Minimum ceiling height is 914 mm from top of unit.

LOCATING YOUR

REGENCY® GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/ Alcove

6

Regency® F39 Room Sealed Freestanding Gas Stove

Page 6
Image 6