INSTALLATION
CONVERSION TO LOWER BTU RATING
THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS
FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
LOG SET
INSTALLATION
Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced.
NG Conversion Kit 730-920
Contains:
Qty. Part # Description
1
1
1
LPG Conversion Kit 730-922
Contains:
Qty. Part # Description
1
1
1
Additional Piece (pkg. with unit:
1Log Bracket Restrictor
1)Shut off the gas supply.
2)Open the front door. Carefully remove the logs and lava rock.
3)Remove burner. See diagram below.
6)Remove burner orifi ce with a 1/2" spanner and discard.
Burner Orifi ce
7)Reinstall new burner orifi ce (NG stamped #37 or LPG stamped #52) and tighten.
8)Reverse steps 3) and 2).
9)Adjust Flue restrictor setting: To set the Flue restrictionasindicatedinthediagram,simply loosen the screws and push the fl ue restric- tor plate to the correct position. Tighten the screws.
Unit | Btu/h | Restrictor Opening |
F39 | 40 Mj/h | A 45mm |
31 Mj/h | B 35mm |
Broken logs can interfere with the pilot operation.
The gas log kit contains the following:
a)
b)
c)
d)
e)
f)
g)
h) | Embers | |
i) | Lava |
Note: Install Optional Brick Panels prior to installing logs.
Note: Use a magnetic
type screwdriver if
possible.
4)Unscrew the 2 Rear Log Pins and move
to the front hole posi- tion.
5)Remove Rear Log Bracketandslidethe
Log Bracket Restric- torbetweentheRear
Log Bracket and the burner, secure with the 2 screws.
Flue Restrictor set- | Flue Restrictor set- |
ting at High Btu/h | ting at Low Btu/h |
10)Attach the label "This unit has been con- verted to..." on top of the data badge over the higher Btu information.
11)Check for gas leaks.
12)Check inlet and outlet pressures.
13)Check operation of fl ame control. Check for proper fl ame appearance on logs.
The "02" refer numbers (i.e. 02-65) are
molded into the rear of each log.
1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.
2)Sprinkle the embers on the left and right sides of the fi rebox base.
EmbersEmbers
Position the Log Bracket Restrictor between
the Rear Log Bracket and the burner.
18 | Regency® F39 Room Sealed Freestanding Gas Stove |