CONVERSION TO LOWER BTU RATING

INSTALLATION

CONVERSION TO LOWER BTU RATING

THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS

FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced.

NG Conversion Kit 730-920

Contains:

Qty. Part # Description

1904-240 Burner Orifi ce #37 (NG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

LPG Conversion Kit 730-922

Contains:

Qty. Part # Description

1904-390 Burner Orifi ce #52 (LPG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

Additional Piece (pkg. with unit:

1Log Bracket Restrictor

1)Shut off the gas supply.

2)Open the front door. Carefully remove the logs and lava rock.

3)Remove burner. See diagram below.

6)Remove burner orifi ce with a 1/2" spanner and discard.

Burner Orifi ce

7)Reinstall new burner orifi ce (NG stamped #37 or LPG stamped #52) and tighten.

8)Reverse steps 3) and 2).

9)Adjust Flue restrictor setting: To set the Flue restrictionasindicatedinthediagram,simply loosen the screws and push the fl ue restric- tor plate to the correct position. Tighten the screws.

Unit

Btu/h

Restrictor Opening

F39

40 Mj/h

A 45mm

31 Mj/h

B 35mm

Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)02-65 Rear Log

b)02-56 Middle Left Log

c)02-44 Front Left Log

d)02-46 Left Top Log

e)02-45 Front Right Log

f)02-47 Center Log

g)02-48 Middle Right Log

h)

Embers

902-151

i)

Lava

902-154

Note: Install Optional Brick Panels prior to installing logs.

Note: Use a magnetic

type screwdriver if

possible.

4)Unscrew the 2 Rear Log Pins and move

to the front hole posi- tion.

5)Remove Rear Log Bracketandslidethe

Log Bracket Restric- torbetweentheRear

Log Bracket and the burner, secure with the 2 screws.

Flue Restrictor set-

Flue Restrictor set-

ting at High Btu/h

ting at Low Btu/h

10)Attach the label "This unit has been con- verted to..." on top of the data badge over the higher Btu information.

11)Check for gas leaks.

12)Check inlet and outlet pressures.

13)Check operation of fl ame control. Check for proper fl ame appearance on logs.

The "02" refer numbers (i.e. 02-65) are
molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the embers on the left and right sides of the fi rebox base.

EmbersEmbers
Position the Log Bracket Restrictor between
the Rear Log Bracket and the burner.

18

Regency® F39 Room Sealed Freestanding Gas Stove

Page 18
Image 18
Regency F39-NG Conversion To Lower Btu Rating, Log Set Installation, This Conversion Must Be Done By An Authorized Gas