6.2. Storage

To set LAM from combat position into a stowed one:

-turn LAM off (operating modes switch (17, Fig.1) should be set to OFF position);

-cover emitter tube output window with protective cap (8, Fig.1);

-disconnect remote switch (Fig.2) from the weapon, loosen screw caps (13, Fig.1), remove LAM with remote switch from Picatinny rail and place it into the case.

LAM in the original packing should be stored in heated premises within the temperature range from +5 to +40°С, relative humidity not higher than 80 % at temperature +25°С.

Battery should be stored separately from LAM.

When preparing for long-term storage, cover the external metal surfaces of LAM with protective lubricant. Each 4 (four) years old layer of lubricant should be removed and new layer applied.

To remove old layer of lubricant:

-Wipe LAM with clean dry cloth,

-Degrease the metal surfaces of LAM with cloth moistened in benzene,

-Dry LAM in the open air.

Do not touch LAM’s metal surfaces with fingers after

cleaning.