AUTOPILOT
11.4.3 Connecting Servo Unit
Servo Unit connections should be according to below drawing.
Note! If any waterproof cable glands do not have cables inserted, install the short
rubber plug provided in order to maintain water tightness. If many options are
connected and not enough glands are available, use a separate junction box and route
the excess wires through one large cable in one of the large glands.
Note! Autopilot instrument / Nexus Network connection. If you want to run the Nexus
Network instruments separate from the Autopilot, do not connect green wire to (pin 1)
to the left in Servo Unit. Instead insulate the green wire.
A-1510
Rudder angle
transmitter
Safty
Rudder
an
swich
Battery Pumpset Jog
Compass
Instrument
g
le
12/24V
DIP
Pumpset/sol
enoid DIP
VR
VR
VR
50
DIP switches:
12/24V DIP:
Right position: 12V
Left position 24V
Pumpset /Solenoid DIP:
Down position: Pumpset or integrated linear drive
Up position: Relay or solenoid system