Settings Menu 4 Chapter

 

TIME CODE [Time code]: Settings related to the time code

 

Description of settings

 

generator

 

 

 

 

 

 

 

 

 

 

 

 

VITC POS SEL-1 [> VITC pos-1]: Select a line to insert the

 

(For DSR-1500A)

 

VITC in.

 

 

 

20 LINE [>> 20 line] to 12 LINE [>> 12 line]: Select any line

 

 

 

 

 

 

from 12 to 20.

 

Note

 

 

 

 

Factory default setting: 16 LINE [>> 16 line]

 

You can insert the VITC signal in two places. To insert it in two

 

 

 

 

 

 

(For DSR-1500AP)

 

places, set both this item and also VITC POS SEL-2.

 

22 LINE [>> 22 line] to 9 LINE [>> 9 line]: Select any line

 

 

 

 

 

 

from 9 to 22.

 

 

 

 

 

 

Factory default setting: 19 LINE [>> 19 line]

 

 

 

 

 

 

VITC POS SEL-2 [> VITC pos-2]: Select a line to insert the

 

(For DSR-1500A)

 

VITC in.

 

 

 

20 LINE [>> 20 line] to 12 LINE [>> 12 line]: Select any line

 

 

 

 

 

 

from 12 to 20.

 

Note

 

 

 

 

Factory default setting: 18 LINE [>> 18 line]

 

You can insert the VITC signal in two places. To insert it in two

 

 

 

 

 

 

(For DSR-1500AP)

 

places, set both this item and also VITC POS SEL-1.

 

22 LINE [>> 22 line] to 9 LINE [>> 9 line]: Select any line

 

 

 

 

 

 

from 9 to 22.

 

 

 

 

 

 

Factory default setting: 21 LINE [>> 21 line]

 

 

 

 

 

 

VITC OUTPUT [> VITC out]: Select the time code to be output

 

OFF [>> OFF]: Do not output VITC.

 

as VITC.

 

 

 

TC [>> TC]: Output TC after converting it into VITC.

 

 

 

 

 

 

*VITC [>> VITC]: Output VITC.

 

 

 

 

 

 

EE OUT PHASE [> EE out]: Determine the output phase for

 

*MUTE [>> mute]: Mute the output.

 

the LTC signal output from the TC OUT connector when

 

THROUGH [>> through]: Output the time code input to the

 

recording time code and in STOP REC mode (forced EE

 

TC IN connector as it is. (See example configuration on

 

mode).

 

 

 

page 70.)

 

 

 

 

 

 

VIDEO INPUT PHASE [>> V input]: Output the time code

 

 

 

 

 

 

with the same phase as the input video signal phase.

 

 

 

 

 

 

(See example configuration on page 70.)

 

 

 

 

 

 

VIDEO OUTPUT PHASE [>> V output]: Output the time code

 

 

 

 

 

 

with the same phase as the output video signal phase.

 

 

 

 

 

 

(See example configuration on page 71.)

 

 

 

 

 

 

MUTE IN SRCH [> Mute in SR]: Select whether to mute the

 

OFF [>> OFF]: Do not mute.

 

output from the TC OUT connector in search (jog/shuttle)

 

*ON [>> ON]: Mute.

 

mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAPE PROTECTION [Tape protct]: Settings related to tape

 

Description of settings

 

and video head protection

 

 

 

 

 

 

 

 

 

 

 

FROM STOP [> From STOP]:

STOP TIMER [>> STP

 

0.5 SEC [>>> 0.5 sec] to 5 MIN [>>> 5 min]: Select time from

 

Set the time to switch from

timer]: Set the time to

 

12 settings ranging from 0.5 second to 5 minutes in steps

 

stop mode to tape protection

switch from stop mode

 

of 0.1 second.

 

mode.

to tape protection

 

Factory default setting: 1 MIN [>>> 1 min]

 

 

 

mode.

 

 

 

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

If the value is set to 1 minute or more, the unit enters internal

 

 

 

 

 

 

protection mode in 1 minute, which makes start up slower.

 

 

 

 

 

 

FROM STILL [> From STILL]:

STILL TIMER [>> STL

 

0.5 SEC [>>> 0.5 sec] to 5 MIN [>>> 5 min]: Select time from

 

Set the time to switch from

timer]: Set the time to

 

12 settings ranging from 0.5 second to 5 minutes in steps

 

still search mode to tape

switch from still search

 

of 0.1 second.

 

protection mode. Also select

mode to tape

 

Factory default setting: 1 MIN [>>> 1 min]

 

the type of tape protection

protection mode.

 

 

 

 

mode.

 

 

 

Note

 

 

 

 

 

 

 

If the value is set to 1 minute or more, the unit enters internal

 

 

 

 

 

 

protection mode in 1 minute, which makes start up slower.

 

 

 

 

 

 

 

 

 

NEXT MODE [>> Next

 

*STEP FWD [>>> Step]: The tape is advanced at 1/30 times

 

 

 

mode]: Select the type

 

normal speed for about 2 seconds.

 

 

 

of tape protection

 

 

 

 

 

STANDBY OFF [>>> STANDBY]: Standby off mode

 

 

 

mode to follow still

 

 

 

 

 

 

 

 

 

 

search mode when the

 

 

 

 

 

 

Note

 

 

 

 

time set with the STILL

 

 

 

 

 

 

The Step setting is enabled only when “STILL TIMER” is set to

 

 

 

TIMER menu item

 

 

 

 

elapses.

 

less than 1 minute.

 

 

 

 

 

 

 

 

64 Menu Contents