Nikon UPS installation instructions Getting Started, Restarting After An Ipl

Models: UPS

1 29
Download 29 pages 20.02 Kb
Page 6
Image 6

UPS/400 . . . an IBM AS/400 UPS power monitoring system . . .

GETTING STARTED

Use the command STRUPS400 to start UPS/400. This will transfer you to the UPS/400 Main Menu.

Because UPS/400 runs within its own subsystem, a userid named UPS400 was set up during the installation process. The userid UPS400 will own the UPS monitoring process and will have a password set to *NONE to assure protection against unauthorized user. This userid has an authority level comparable to QSECOFR but cannot be QSECOFR. To review this user profile, enter DSPUSRPRF USRPRF(UPS400).

To execute UPS/400, a user must (a) be within one of the following user classes: *SECADM, *SECOFR, *SYSOFR, or (b) have a special authority of *ALLJOB or *SECADM.

RESTARTING AFTER AN IPL

To use UPS/400 startup program, the IBM system value QSTRUPPGM should be set to Program QSTRUP in UPS400. This will allow UPS/400 to restart itself after IPLs. You may elect to use the UPS/400 Autostart Job at any time by pressing F10 while on the UPS/400 System Attributes screen or you can include the supplied source code (UPS400/UPSSRC member QSTRUP) in your own start-up program.

6

Page 6
Image 6
Nikon UPS installation instructions Getting Started, Restarting After An Ipl