| Fault |
| Cause | Remedy |
‡ | The acoustic warning | > | Filter element is clogged. | • See section 4.5/4.6 „Cleaning |
| sounds. (Reduced suction |
|
| filter element“ and 7.2.5/7.2.6 |
| power) |
|
| „Replacing filter element“. |
|
| > | IVB | • Contact Nilfisk Advance Ser- |
|
|
| Defective cleaning mecha- | vice |
|
|
| nism |
|
|
|
|
| |
‡ No suction power during | > | Tank is full. (Float does not | • Switch off the cleaner. Empty | |
| wet cleaning |
| close the suction opening). | the tank. |
|
|
|
|
|
‡ | The vacuum cleaner | > | Tank is full. | • Switch off the cleaner. Empty |
| switches off during wet |
|
| the tank. |
| cleaning |
|
|
|
|
|
|
|
|
‡ | Voltage fluctuations | > | Impedance of power supply is | • Connect the cleaner to an- |
|
|
| too high. | other socket closer to the fuse |
|
|
|
| box. Voltage fluctuations over |
|
|
|
| 7% should not occur if the im- |
|
|
|
| pedance at the transfer point |
|
|
|
| is ≤ 0.15 Ω . |
|
|
|
|
|
9 Further information
9.1Recycling the vacuum Make the old cleaner unusable
cleaner |
|
| immediately. | |
|
|
|
| 1. Unplug the cleaner and cut |
|
| |||
|
|
|
| the power cord. |
|
| |||
|
|
|
| Do not discard of electrical ap- |
|
|
|
| |
|
|
|
| |
|
|
|
| pliances with household waste. |
|
|
|
| As specified in European Direc- |
|
|
|
| tive 2002/96/EC on old electrical |
9.2 Guarantee |
|
| Our general conditions of busi- | |
|
|
|
| ness are applicable with regard |
|
|
|
| to the guarantee. Subject to |
|
|
|
| change as a result of technical |
|
|
|
| advances. |
and electronic appliances, used electrical goods must be col- lected separately and recycled ecologically.
Contact your local authorities or your nearest dealer for further information.
9.3Tests and approvals The vacuum cleaners have been tested as specified in IEC/EN
The vacuum cleaners must be inspected regularly in accord- ance with national accident pre- vention regulations (in Germany as specified in BGV A2 and DIN VDE 0701 Part 1 and Part 3, at regular intervals and after re- pairs or modifications).
A dust test must be performed at least once every year by the manufacturer or a trained per- son. This test covers, for exam- ple, whether there is damage to the filter, the vacuum cleaner is sealed to the air and the control equipment works properly.
14 | 1) Option depending on model |