Precautions and safety regu- lations when using the vacu-
|
|
|
|
|
|
|
|
|
|
|
| Dust Class M (medium). | tested in its entirety by vacuums |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| The dusts which belong | for this dust class. The maximum |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| to this class are: dusts | degree of permeability is 0.1% |
|
|
|
|
|
|
|
|
|
|
|
| ||
with OEL values > 0.1 mg/m³ as | and the disposal must be low | ||||||||||||
well as saw dust. The machine is | dust. | ||||||||||||
Before | Electrical components |
IVB
english
um cleaner
Inspect power cord regularly to detect signs of damage, e.g. cracks or ageing.
If the power cord is damaged, it must be replaced by Nilfisk Advance Service or an electri- cian to avoid danger before use of the vacuum cleaner is continued.
Use only the type of power cord specified in the operating manual.
Do not damage the power cord (e.g. by moving over it or pulling or crushing it).
Disconnect the power cord by pulling the plug only (do not pull or tug the power cord).
Inspect the vacuum cleaners to ensure that they are in proper condition. Plugs and couplings in power cords must at least have splash protection.
Never use the vacuum cleaner if the filter element is damaged.
Picking up liquids
If foam develops or liquid emerges, stop work immediately and empty the dirt tank.
Regularly clean the built in float (IVB
See section 5 for information on handling liquids and (hazard- ous) dust.
Check the rated voltage of the vacuum cleaner before con- necting it to the mains supply system. Ensure that the voltage shown on the rating plate cor- responds to the voltage of the local mains power supply.
If you are using an extension cord, use only those specified by the manufacturer or higher quality ones (see section 9.4 „Technical data“).
It is recommended that the vacuum cleaner should be con- nected via a residual current circuit breaker. This stops the supply of electricity if the leak- age current to earth exceeds 30 mA for 30 ms or it has an earth tester circuit.
When using an extension lead, check the minimum
Cable length | Cross section | ||
m |
|
| |
<16 A | <25 A | ||
| |||
|
|
| |
up to 20 m | ø1.5mm² | ø2.5mm² | |
|
|
| |
20 to 50 m | ø2.5mm² | ø4.0mm² | |
|
|
|
Arrange the electrical parts (sockets, plugs and couplings) and lay down the extension lead so that the protection class is maintained.
Never spray water on to the upper section of the vacuum cleaner. Danger for persons, risk or
Observe the latest edition of the IEC regulations.
1) Option depending on model | 03 |