Nilfisk-Advance America IVB 7-M, IVB 5-M, IVB 3-M Before start-up, Operation, Operating elements

Models: IVB 3-M IVB 7-M IVB 5-M

1 18
Download 18 pages 51.27 Kb
Page 7
Image 7
2.2 Operating elements

2.2 Operating elements

See fold-out page at the front of

6

Dirt tank

 

these operating instructions.

7

Grip to empty tank1)

 

 

 

8

Inlet fitting

 

1

Handle

9

Appliance socket1)

 

2

Suction pipe support

10

Cable hook

 

3

Accessory holder

11

Operating knob for filter

 

4

Applicance switch with

 

cleaning1)

 

 

suction power control

12

Tank locks1)

 

5

Retaining clamp

13

Castor with brake

 

 

 

14

Hose diameter setting

IVB 3-M IVB 5-M IVB 7-M

english

3 Before start-up

3.1 Assembling the cleaner

On delivery some of the accesso- ries are lying in the tank and must be removed before the vacuum cleaner is used for the first time.

Remove the upper section of the vacuum cleaner:

The mains plug should not be in- serted into a socket.

1. Open the retaining clamps and lift off the upper section of the cleaner.

2. Take the accessories out of the dirt tank and the packag- ing.

3.To pick up dust with maxi- mum room concentration values:

Insert the filter bag into the dirt tank according to the instructions (instructions in- cluded).

To pick up harmless dust: Insert the disposal bag (in-

structions included) into the tank.

IMPORTANT:

P r e s s

the filter bag

connection

firmly on to the inlet fitting.

4.Fit the upper section of the vacuum cleaner and close the retaining clamps.

NOTE: Ensure that the retaining clamps fit properly.

4 Operation

4.1Connections

4.1.1Connecting the suction hose

The suction hose diameter must suit the position of the switch in order to pick up dry, nonflammable dust with maximum room concen- tration values.

4.1.2 Electrical connection

The operating voltage shown on the rating plate must correspond to the voltage of the mains power supply.

1. Connect the suction hose.

1.Ensure that the vacuum cleaner is switched off.

2.Insert the power cord into a properly installed and fused socket with an earthing con- tact.

1) Option depending on model

05

Page 7
Image 7
Nilfisk-Advance America IVB 7-M, IVB 5-M, IVB 3-M Before start-up, Operation, Operating elements, Assembling the cleaner