Nilfisk-Advance America 56422001 ENGLISH / A-13, Charging The Batteries, To Charge the Batteries

Models: 56422002 56422001 2710 56422000 UHR 70-1700

1 30
Download 30 pages 37.41 Kb
Page 13
Image 13
ENGLISH / A-13

ENGLISH / A-13

CHARGING THE BATTERIES

Charge the batteries each time the machine is used for 1 hour or longer, or whenever the Battery Condition Indicator Lights (B) light up red.

To Charge the Batteries...

1IMPORTANT!: Open the Battery Compartment Cover (13) to provide proper ventilation.

2Disconnect the Battery Connector Assembly (7) and plug the battery charger into the plug connected to the batteries.

4Follow the instructions on the battery charger.

5Check the fluid level in all battery cells after charging the batteries. Add distilled water, if necessary, to bring the fluid level up to the bottom of the filler tubes.

CHARGING THE BATTERIES WARNING!

Do not fill the batteries before charging.

Charge batteries in a well-ventilated area.

Do not smoke while servicing the batteries.

When Servicing Batteries...

*Remove all jewelry

*Do not smoke

*Wear safety glasses, rubber gloves and a rubber apron

*Work in a well-ventilated area

*Do not allow tools to touch more than one battery terminal at a time

*ALWAYS disconnect the negative (ground) cable first when replacing batteries to prevent sparks.

*ALWAYS connect the negative cable last when installing batteries.

To Charge the Batteries... CAUTION!

To avoid damage to floor surfaces, wipe water and acid from the top of the batteries after charging.

CHECKING THE BATTERY WATER LEVEL

Check the water level of the batteries at least once a week.

After charging the batteries, remove the vent caps and check the water level in each battery cell. Use distilled or demineralized water in a battery filling dispenser (available at most auto parts stores) to fill each cell to the level indicator (or to 10 mm over the top of the separators). DO NOT over-fill the batteries!

CHECKING THE BATTERY WATER LEVEL CAUTION!

Acid can spill onto the floor if the batteries are overfilled.

Tighten the vent caps. Wash the tops of the batteries with a solution of baking soda and water (2 tablespoons of baking soda to 1 liter of water). Service Note: There is a drain plug in the bottom of the battery compartment.

FORM NO. 56041634 - Advolution™ 2710 / UHR 70-1700 - A-13