4.3Cleaning the filter element
4.3.1Cleaning the filter element " Push&Clean System "
(ATTIX 30- / 50-xx PC)
Only for vacuum cleaning without a filter bag and without a cloth insert filter.
ATTIX 30/50 H/M
english
Filter Cleaning System
If suction performance drops:
1.Turn switch to position "I" (maximum suction power).
2.Close the nozzles or suction hose opening with the palm of your hand.
3.Press the button to start filter
cleaning three times. The re- sulting stream of air removes attached dust from the slats of the filter elements.
4.3.2Cleaning the filter element " XtremeClean " (ATTIX
Only for vacuum cleaning without a cloth insert filter.
After picking up harmless dust using the waste bag.
10 sec . |
4.3.3Check the volume flow monitor
Before picking up dust with maxi- mum room concentration values:
To ensure that suction perform- ance is always at its best, the filter element is automatically cleaned during operation. We recommend complete cleaning if the filter element becomes ex- tremely dirty.
1.Check that all the filters are present and properly fitted.
1.Switch off the vacuum clean- er.
2.Close the nozzles or suction hose opening with the palm of your hand.
3.Turn the switch to position „I“ and let the cleaner operate for approx. 10 seconds with the suction hose opening closed.
2.When the motor is run- ning, hold the suction hose shut. An acoustic warning sounds after approx. 1 sec- ond.
4.3.4 Acoustic warning
For safety reasons, an acoustic | low 20 m/s. See section "Trou- |
warning sounds if the air speed | bleshooting" |
in the suction hose drops to be- |
|
15