Nilfisk-ALTO 30 H Transport, Storage, Electrical connection, Extension lead, Cable length, 16 A

Models: 30 H 30 M

1 32
Download 32 pages 39.94 Kb
Page 5
Image 5
Transport

ATTIX 30/50 H/M

english

Dust Class M (medium). The dusts which belong to this class

StorageElectrical connectionExtension leadCable lengthCross section< 16 A are: dusts with OEL values1) > 0.1 mg/m³ as well as saw dust. < 25 AManual backgroundManual background The machine is tested in its entirety by vacuums for this dust class. The maximum degree of permeability is 0.1% and the dis-

posal must be low dust.

The air flow in Safety Vacuum systems has to be strictly controlled to achieve a minimum flow rate of Vmin = 20 m/s in the suction hose.

The vacuum cleaners ATTIX 30-XH and ATTIX 50-XH are suitable to pick up

dry, nonflammable dust, non flammable liquids, hazadous dusts with OEL values, carcinogenic dusts, dusts containing germs

The vacuum cleaners ATTIX 30-XH PC e ATTIX 50-XH PC are also approved for asbestos abatement (TRGS 519).

The vacuum cleaners ATTIX 30-XM and ATTIX 50-XM are suitable to pick up

dry, nonflammable dust, non flammable liquids, sawdust and hazadous dusts with OEL values > 0.1 mg/m³

The vacuum cleaners are suitable for commercial use, such as e.g. in

Hotels, Schools, Hospitals, Factories, Shops, Offices, Hire shops

Any other use is considered as improper use. The manufacturer ac- cepts no liability for any damage resulting for such use. The risk for such use is borne solely by the user.

Proper use also includes proper operation, servicing and repairs as specified by the manufacturer.

Transport

1.

Before transporting the dirt tank, close all the locks.

 

2.

Do not tilt the cleaner if there is liquid in the dirt tank.

 

3.

Do not use a crane hook to lift the cleaner.

 

Storage

1.

Store the appliance in a dry place, protected from frost.

Electrical connection

1.

It is recommended that the vacuum cleaner should be connected

 

 

 

via a residual current circuit breaker.

 

 

2.

Arrange the electrical parts (sockets, plugs and couplings) and

 

 

 

lay down the extension lead so that the protection class is main-

 

 

 

tained.

 

 

 

 

3.

Connectors and couplings of power supply cords and extension

 

 

 

leads must be watertight.

 

 

 

Extension lead

1.

As an extension lead, only use the version specified by the man-

 

 

 

ufacturer or one of a higher quality. See operating instructions.

 

2.

When using an extension lead, check the minimum cross-sec-

 

 

 

tions of the cable:

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable length

 

Cross section

 

 

 

 

 

< 16 A

 

< 25 A

 

 

up to 20 m

 

1.5 mm2

 

2.5 mm2

 

 

20 to 50 m

 

2.5 mm2

 

4.0 mm2

Maintenance, cleaning and During the following work, ensure that dust is not unnecessarily

repairspread around. Wear a P2 bresthing mask.

CAUTION: In the case of asbestos abatement wear additional sin- gle-use clothing.

3