Rear Squeegee Blade Replacement
If the rear squeegee blade is worn and does not dry the
floor well, follow this procedure:
1. Remove the squeegee assembly from the
machine.
2. Remove the squeegee blade and inspect it.
3. Rotate the squeegee blade to obtain a new
cleaning edge. Replace if necessary.
4. Reinstall the squeegee blade.
5. Reinstall the squeegee assembly on the
machine.
6. Readjust the settings on the squeegee as
required (see “How to Adjust Squeegee”).
Squeegee Maintenance
The squeegee blade may be rotated for longer life.
Keep sharp corner on floor for best cleaning
results. See figure 40. To rotate follow this
procedure:
1. Remove Clamp.
2. Remove blade and rotate to new edge.
3. Replace squeegee.
4. Replace clamp.
Cleaning the Vacuum Hoses
Make sure the squeegee is over a suitable drain.
1. Use a water hose to flush through the recovery
hoses.
2. Side Squeegee - Position water hose to the
squeegee side of the hose and flush thoroughly.
3. Recovery Hose - Position water hose
inside recovery tank. Recovery hose is located
behind threaded lip (see figure 40, A). NOTE: Do
not place hose in vacuum intake tube (see
figure 41, B), damage will occur.
Maintenance
Figure 40
Figure 41