1. TROUBLESHOOTING

 

Table 1.

Troubleshooting

 

 

 

 

 

 

Part

Possible Failure

 

Symptoms

Solution

 

 

 

 

 

Vacuum Valve

Diaphragm Failure

 

Nozzle sputter.

Replace defective

 

 

 

Low output.

component.

 

 

 

 

 

 

 

No output.

 

 

 

 

 

 

 

Pilot Safety Regulator

 

Nozzles sputter.

Repair regulator using

 

Diaphragm Ripped

 

Air in water line.

repair kit.

 

 

 

 

 

 

 

Low output.

 

 

 

 

No Output.

 

 

 

 

Water drips from bonnet.

 

 

 

 

 

 

 

Valve Seat O-Ring

 

Pressure water line resulting

Replace o-ring, rebuilt

 

 

 

in heavy mist.

vacuum valve.

 

 

 

Could damage main

 

 

 

 

diaphragm.

 

 

 

 

No control of output.

 

 

 

 

 

 

 

Other O-rings

 

Vacuum leak, low output, no

Replace.

 

 

 

output.

 

 

 

 

Water leaks out.

 

 

 

 

 

 

 

Cracked Housing

 

Vacuum leak or water dripping

Replace damaged

 

 

 

from valve.

component.

 

 

 

 

 

 

Blockage

 

Reduced output.

Clean.

 

 

 

No output.

 

 

 

 

 

 

Pilot Air

Damaged Diaphragm

 

Loss in air pressure.

Repair.

Regulator

 

 

No air pressure.

 

 

 

 

 

 

 

 

Uncontrolled air pressure.

 

 

 

 

 

 

 

Stuck Closed Or Open

 

Unable to adjust pressure.

Disassemble and clean.

 

 

 

 

 

Pilot Water

Damaged Diaphragm

 

Loss in water pressure.

Repair.

Regulator

 

 

No water pressure.

 

 

 

 

 

 

 

 

Uncontrolled water pressure.

 

 

 

 

 

 

 

Stuck Closed Or Open

 

Unable to adjust pressure.

Disassemble and clean.

 

 

 

 

 