Alteon OS Application Guide

Viewing and Configuring PVIDs

Use the following CLI commands to view PVIDs:

„Port information:

Alias Port Tag Fast PVID

NAME

VLAN(s)

--------- --- ---- ---- -------------- ----------------------------

---

INT1

1

n

n

1

INT1

1

INT2

2

n

n

1

INT2

1

INT3

3

n

n

1

INT3

1

INT4

4

n

n

1

INT4

1

INT5

5

n

n

1

INT5

1

INT6

6

n

n

1

INT6

1

INT7

7

n

n

1

INT7

1

INT8

8

n

n

1

INT8

1

INT9

9

n

n

1

INT9

1

INT10

10

n

n

1

INT10

1

INT11

11

n

n

1

INT11

1

INT12

12

n

n

1

INT12

1

INT13

13

n

n

1

INT13

1

INT14

14

n

n

1

INT14

1

MGT1

15

n

n

4095

MGT1

4095

MGT2

16

n

n

4095

MGT2

4095

EXT1

17

n

n

1

EXT1

1

EXT2

18

n

n

1

EXT2

1

EXT3

19

n

n

1

EXT3

1

EXT4

20

n

n

1

EXT4

1

EXT5

21

n

n

1

EXT5

1

EXT6

22

n

n

1

EXT6

1

EXT7

23

n

n

4094

EXT7

4094

* = PVID is tagged.

NOTE The sample screens that appear in this document might differ slightly from the screens displayed by your system. Screen content varies based on the type of BladeCenter unit that you are using and the firmware versions and options that are installed.

„Port Configuration:

>>/cfg/port INT7/pvid 7

Current port VLAN ID: 1

New pending port VLAN ID: 7

>>Port INT7#

78 „ Chapter 3: VLANs

42C4911, January 2007

Page 78