The loop number and location of the primary and secondary clock source is configured in the Digital Data Block overlay 73. Refer to the ISDN Basic Rate Interface: Administration (553-3901-300).

The following procedure should be followed to provide clock referencing on the SILC.

Note: For procedures on how to install the QPC775/QPC471 Clock Controller on the various Meridian 1 systems, please refer to ISDN PRI: Installation (553-2901-201).

1Maintain the same polarity on each transmit and receive. Rewire the selected Tx and Rx pairs (applicable to DSL0 and DSL1), to exchange the Tx and Rx pair position. This rewiring is done at the Main Distribution Frame (MDF).

2Remove the phantom power jumpers (two jumpers per DSL) from the pin headers.

3Place the SILC in the selected IPE slot.

4Configure the selected DSL as TE mode (in overlay 27).

5Enable the clock in overlay 60, to output the clock references to the IPE back plane pins.

6Configure the Clock Controller card to accept ISDN BRI clock reference.

7Check the appropriate messages from the Clock Controller to ensure that it is synchronized to the proper clock reference (this is done using overlay 60).

8Connect the ISDN BRI clock reference cables to the Clock Controller, using the procedures which follow.

—————————— End of Procedure ——————————