Nortel Networks 553-3901-200 instruction manual Install Isdn BRI hardware Page 27

Models: 553-3901-200

1 48
Download 48 pages 6.23 Kb
Page 27
Image 27

Install ISDN BRI hardware Page 27 of 46

Table 2

SILC port designations at the MDF: NT8D37 IPE Module (16-cable configuration) (Part 2 of 2)

14

 

 

 

 

 

 

 

 

T T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R

T

0

1

2

3

4

5

6

7

 

15

 

 

 

 

 

 

 

 

U T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R-

T-T+R+R

U

0

1

2

3

4

5

6

7

 

 

 

 

 

 

 

 

 

 

Note 1: For the SILC port designations shown in this table, substitute Tx- Tx+ Rx+ Rx- for every occurrence of T- T+ R+ R-.

Note 2: The cable pair designated Tx- Tx+ is the transmit pair. The pair designated Rx+ Rx- is the receive pair. An SILC port supplies 2 watts of power at -48 V (-40 V for international), simplexed over the transmit and receive pairs, where the transmit pair is negative with respect to the receive pair.

Table 3

UILC port designation labels at the MDF: NT8D37 IPE Module (16-cable configuration) (Part 1 of 2)

0

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

A

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

B

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

C

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

D

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

E

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

F

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

G

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

H

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

TR

 

K

 

 

 

 

 

 

 

 

 

 

0

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ISDN Basic Rate Interface Installation

Page 27