![](/images/new-backgrounds/1119589/11958979x1.webp)
Page 40 of 46 Install ISDN BRI hardware
Connect clock reference cables
The following procedure should be followed to connect the ISDN BRI clock reference cables to the Clock Controller. There are three different cables that route clock signals from the IPE back plane to the Clock Controller face plate (as shown in Figure 11). These are shown in Table 7.:
Table 7
ISDN BRI clock reference tables
Code | Length (feet) | Use |
|
|
|
NTND70AA | 1.5 | Connects IPE back plane to |
|
| IPE I/O panel. |
|
|
|
6.5, 12, 25, 42 | Connects IPE I/O to CE I/O | |
|
| panel. |
|
|
|
NTND72AA | 6.5 | Connects CE I/O to Clock |
|
| Controller face plate. |
|
|
|
Note: Measure the distance between the IPE and CE modules to ensure that you order the correct cable lengths.
1Search for available
2Connect the cables as shown in Figure 11; if choosing IPE slots 0, 4, 8, or 12 the transmit and receive cable installed on pins 72 - 79 should be removed and secured to a proper place.