Nortel Networks Confidential

Configuration Management 31

 

 

Figure 6 SimRing configuration procedure flow

Enable

Assign

View

SimRing

SimRing

SimRing

on switch

to a line

status

Enabling SimRing on the DMS

Before adding SimRing to a line, make sure that table OFCENG is datafilled properly in order for SimRing to work. Sample datafill is shown below:

>TABLE OFCENG

MACHINES NOT IN SYNC - DMOS NOT ALLOWED JOURNAL FILE UNAVAILABLE

-DMOS NOT ALLOWED TABLE: OFCENG

>POS SIMRING_RES_CONTROL

SIMRING_RES_CONTROLY N

>POS SIMRING_CENTREX_CONTROL SIMRING_CENTREX_CONTROLY N

>POS NO_OF_CLONE_TIDS NO_OF_CLONE_TIDS 20

For detailed engineering information about configuring these OFCENG tuples correctly, please refer to the North American DMS-100 Translations Guide Volume 17 of 20 (Document Number:

297-8001-350).

Assigning SimRing on a DMS line

To assign SimRing to an existing line, use the EST (establish) command of SERVORD.

>SERVORD

 

 

SO:

 

 

>EST

 

 

SONUMBER:

NOW

0 8 16 PM

>$

 

 

GROUPTYPE:

 

 

>SIMRING

 

 

SIMRING_PILOT_LEN: >HOST 0 1 10 5

SIMRING_MEMBER_DN: >6215115

SIMRING_MEMBER_DN: >6215010

SIMRING_MEMBER_DN: >$

SIMR_STATE: INACT

Copyright © 2003, Nortel Networks

MCP Interworking Basics

Page 31
Image 31
Nortel Networks NN10033-111 manual Assign, SimRing On switch To a line, Enabling SimRing on the DMS