8Chapter 2 DN configuration requirements for the BST Doorphone

Use Table 2 to set line access parameters for the BST Doorphone.

Table 2 Line access parameters

Tab

Attribute

Values

Description

 

 

 

 

Main panel

Fwd No Answer

up to 24 digits

Leave blank for the BST Doorphone.

 

 

 

 

 

Fwd Busy

up to 24 digits

Leave blank for the BST Doorphone.

 

 

 

 

Line Assignment

Line

read only

Ensure there is no line assignment for this DN.

 

 

 

 

Line Pool

Line Pool

read only

Ensure that no line pool access is selected for this DN.

Access

 

 

 

 

 

 

 

Answer DNs

DN

DN number

Ensure that there are no Answer DN assignments for

 

 

 

the BST Doorphone.

 

 

 

 

4Select the Capabilities and Preferences tab and select the DN. Additional tabs display in the details panel. You must set parameters in the main panel and under the following tabs:

Capabilities

Preferences

Use Table 3 to set the capabilities and preferences for the BST Doorphone.

5Repeat these steps for every BST Doorphone you plan to install on the system.

Table 3 Capabilities and preferences

Tab

Attribute

Values

Description

 

 

 

 

Main panel

Prime line

I/C

Ensure that the prime line value is set to I/C for the

 

 

 

BST Doorphone.

 

 

 

 

 

Intercom (I/C)

1

Assign only one intercom key to the BST Doorphone.

 

keys

 

 

 

 

 

 

 

Control set

None

Set this value to None for the BST Doorphone.

 

 

 

 

Capabilities

DND on busy

check box

Ensure that this check box is not selected for the BST

 

 

 

Doorphone.

 

 

 

 

 

Handsfree

None

Set this value to Auto for the BST Doorphone.

 

 

Standard

 

 

 

Auto

 

 

 

 

 

 

Paging

check box

Ensure that this check box is selected for the BST

 

 

 

Doorphone.

 

 

 

 

 

Direct dial

0 - 9

Set this value to 0 for the BST Doorphone.

 

 

 

 

Preferences

Aux ringer

check box

Ensure that this check box is not selected for the BST

 

 

 

Doorphone.

 

 

 

 

 

Hotline type

None

Ensure that the Hotline type is sent to None.

 

 

Internal

 

 

 

External

 

 

 

 

 

Note: For a detailed explanation on all line access fields, refer to your BCM Configuration Guide.

NN40010-302

Page 8
Image 8
Nortel Networks NN40010-302 manual Use to set line access parameters for the BST Doorphone