Figure 5: MIC to OEM-IMU-STIM300 (OEM Cable Kit: 01019174)

MIC

IMU

 

MIC to IMU Interface

Cable (01019161)

INSTALL THE MIC IN A STACK UP CONFIGURATION

In a stack up configuration, the MIC is connected directly to an OEM615 receiver. Power and communications connections to the receiver are made through the MIC.

3

MIC

4

5

1

6

7

 

 

2

 

 

OEM615

 

 

 

 

 

 

Ref

Connector

Part Number

Mating Connector

Description

1

P101

43650-0313

43645-0300

Connects to the power supply

 

 

(Molex)

(Molex)

(user supplied cable)

2

J101

MCX-J-P-H-ST-SM1

M1051-110

Connects to the GNSS antenna

 

 

(Samtec)

(ShinA Telecom)

(user supplied cable)

3

P301

501571-3007

501189-3010

Connects to COM and USB ports

 

 

(Molex)

(Molex)

LVTTL (not 5 V tolerant) (user supplied cable)

3

Page 3
Image 3
Novatel GM-14915118 quick start Mic, Install the MIC in a Stack UP Configuration