NuTone IM-440 Series Connecting The Power Transformers, Mounting The Transformer Cover

Models: IM-440 Series

1 20
Download 20 pages 40.13 Kb
Page 7
Image 7
CONNECTING THE

INSTALLATION (Continued)

CONNECTING THE

POWER TRANSFORMERS

CAUTION

 

 

BE SURE THE AC POWER IS OFF BEFORE CONNECTING THE POWER TRANSFORMERS. DO NOT TURN AC POWER ON TO TRANSFORMERS UNTIL ALL WIRING AT THE REMOTE AND MASTER STATIONS IS COMPLETE!

1.Refer to Figure 14. The transformers’ primary leads should already be connected to the 120 volt AC house supply wiring. Be sure power is off before connecting transformers to master unit.

IMPORTANT WARNING!

THE POWER TRANSFORMER CONTAINS AN INTERNAL FUSE.

DO NOT SHORT THE LOW VOLTAGE CONNECTING SCREWS OF THE TRANSFORMER OR THE TRANSFORMER WILL BE DESTROYED!

2.Locate the two (2) sets of red/wht transformer leads on the lower left corner of the master unit. Connect one pair of low voltage leads to each transformer located in the bottom of the rough-in.

MOUNTING THE TRANSFORMER COVER

IMPORTANT: The transformer cover must be installed for proper operation of the intercom.

1.Refer to Figure 15. Remove the left front and right rear screws from the transformer enclosure. Set screws aside for later installation.

2.Position the transformer cover (with insulator positioned towards transformers) over the transformer enclosure so holes in cover align with holes in enclosure.

3.Fasten cover with two (2) screws previously removed.

FIGURE 14

FIGURE 15

7

Page 7
Image 7
NuTone IM-440 Series Connecting The Power Transformers, Mounting The Transformer Cover, INSTALLATION Continued