LightJet 500XL Maintenance Guide ×
5.If the filter is damaged, replace it. Contact Océ (see “Product Support, Documentation and Service” on page ii) for a replacement filter (part #39958).
6.
Coalescing Filter
The coalescing filter is located just inside the right side door. Examine the filter monthly, checking for the following:
§Dirt
§Liquid or oil in the bowl - should not be above the lower baffle holding the filter element.
§Differential pressure indicator - should not extend more than half way into the clear dome located above the retaining ring on top of the filter body.
If one or more of the above conditions exists, replace the coalescing filter. Otherwise, replace once per year. To examine or replace the coalescing filter:
CAUTION CAUTION: THE FILTER CONTAINER IS UNDER PRESSURE (60 PSI). TURN OFF THE HOUSE AIR SUPPLY AND DEPRESSURIZE ALL AIR LINES CONNECTED TO THE FILTER ASSEMBLY. THERE IS A RISK OF PERSONAL INJURY IF RELEASED UNDER PRESSURE.
ATTENTION: LA CARTOUCHE DU FILTRE EST SOUS PRESSION (4.1 BAR). DÉCONNECTEZ LA SOURCE D'ALIMENTATION D'AIR COMRIMÉ ET DÉPRESSURISEZ TOUTES LES LIGNES À AIR CONNECTÉES AU PORTE- FILTRE. IL EXISTE UN RESQUE DE BLESSURE SI LE
VORSICHT: DER LUFTFILTER IST UNTER DRUCK (4,1 BAR). DIE LUFTZUFUHR MUSS ABGESTELLT UND DIE LEITUNGEN ZUM LUFTFILTER ENTLEHRT WERDEN. ES BESTEHT VERLETZUNGSGEFAHR SOLLTE ER UNTER DRUCK GEÖFFNET WERDEN.
1.Shut off the house air supply and depressurize the machine by disconnecting the 6 mm (¼”) air hose from the bulkhead tube connector on the right side of the machine.
2.Open the right side door to access the drum.
3.Unscrew the threaded collar and carefully remove the bowl.
4.Clean (using mild soap and water only) and thoroughly dry all internal parts and the bowl before reassembling.
If a new filter element is required:
1.Unscrew the lower baffle and remove the old filter element. Insert the new filter element and replace the lower baffle; tighten firmly.